Failure of the 1553 Data Bus between GCU 1 and GAPCU
TASK 24-22-00-810-829-A
Failure of the 1553 Data Bus between GCU 1 and GAPCU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-22-00-740-075-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 24-22-00-810-084-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:38 UTC
Failure of the 1553 Data Bus between GCU 1 and GAPCU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-22-34-000-001 | Removal of the GCU-1(2) |
| AMM 24-22-34-400-001 | Installation of the GCU-1(2) |
| ASM 242302 | |
| AMM 24-41-00-740-002 | Operational Check of the GAPCU via the CFDS |
| AMM 24-41-34-000-001 | Removal of the Ground Power Control Unit (GPCU) |
| AMM 24-41-34-400-001 | Installation of the Ground Power Control Unit (GPCU) |
Subtask 24-22-00-740-075-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 24-22-00-810-084-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message GCU1 (1XU1) 1553 BUS/ GAPCU (24XG):
Subtask 24-22-00-740-076-A ** ON A/C NOT FOR ALL - replace the GCU-1 [1XU1] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
- replace the GAPCU [24XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
- do a check and repair the wiring of the 1553 data bus ASM 242302 for an open circuit, a short to ground, a short to shield or a short circuit between:
. pin A/6J of the GCU 1 and pin A/11E of the GAPCU
. pin A/6H of the GCU 1 and pin A/12E of the GAPCU
. pins A/11E and A/10E of the GAPCU (short to shield)
. pins A/12E and A/10E of the GAPCU (short to shield).
B. Do the test given in Para. 3.