Failure of the Generator Control Unit 2
TASK 24-22-00-810-822-A
Failure of the Generator Control Unit 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-22-00-740-067-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 24-22-00-810-080-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:38 UTC
Failure of the Generator Control Unit 2
1. Possible Causes
- GCU-2 [1XU2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-22-34-000-001 | Removal of the GCU-1(2) |
| AMM 24-22-34-400-001 | Installation of the GCU-1(2) |
| AMM 24-41-00-740-002 | Operational Check of the GAPCU via the CFDS |
Subtask 24-22-00-740-067-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 24-22-00-810-080-A ** ON A/C NOT FOR ALL
A. If the Class 3 Faults gives the maintenance message GCU2 (1XU2):
Subtask 24-22-00-740-068-A ** ON A/C NOT FOR ALL - replace the GCU-2 [1XU2] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
B. When you replace a component or repair the wiring:
- do the subsequent flight before you do the check of the Class 3 Faults of the GAPCU from the CFDS to make sure that the system operates correctly.
If the test continues to give the fault message, continue the trouble shooting procedure.