W DOC AIRBUS | TSM A320F

Failure of the Generator Control Unit 1


TASK 24-22-00-810-821-A
Failure of the Generator Control Unit 1


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-22-34-000-001
Removal of the GCU-1(2)
AMM 24-22-34-400-001
Installation of the GCU-1(2)
AMM 24-41-00-740-002
Operational Check of the GAPCU via the CFDS
3. Fault Confirmation
Subtask 24-22-00-740-065-A ** ON A/C NOT FOR ALL
A. Test
   (1) Read the Class 3 Faults of the GAPCU from the CFDS AMM 24-41-00-740-002.
4. Fault Isolation
Subtask 24-22-00-810-079-A ** ON A/C NOT FOR ALL
A. If the Class 3 Faults gives the maintenance message GCU1 (1XU1):
Subtask 24-22-00-740-066-A ** ON A/C NOT FOR ALL
B. When you replace a component or repair the wiring:
  • do the subsequent flight before you do the check of the Class 3 Faults of the GAPCU from the CFDS to make sure that the system operates correctly.
    If the test continues to give the fault message, continue the trouble shooting procedure.