Failure of the GCU 2
TASK 24-22-00-810-804-A
Failure of the GCU 2
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 24-22-00-710-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 24-22-00-810-053-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:34 UTC
Failure of the GCU 2
1. Possible Causes
- GCU-2 [1XU2]
- sockets of the 400VC1
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | DYNAMOMETER 15 DAN (33 LBF) - PULL |
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2048230 | |
| AWM 242201 | |
| AMM 24-22-34-000-001 | Removal of the GCU-1(2) |
| AMM 24-22-34-400-001 | Installation of the GCU-1(2) |
| AMM 24-41-00-740-004 | Operational Check of the GPCU via the CFDS |
Subtask 24-22-00-710-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 24-22-00-810-053-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message GEN2 FAULT:
- do a check of the voltage of each phase.
- replace the GCU-2 [1XU2] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
- do a pin retention check ESPM 2048230 of the sockets of the 400VC1 AWM 242201. Use a DYNAMOMETER 15 DAN (33 LBF) - PULL, the CANNON value is 1.2 daN (2.7 lbf) minimum and the SOURIAU value is 2.8 daN (6.3 lbf) minimum, in relation to pin/socket type used.