Failure of the IDG Cooler 2


TASK 24-21-00-810-829-A
Failure of the IDG Cooler 2


1. Possible Causes
  • FUEL/OIL HEAT EXCHANGER
  • IDG 2 oil-cooling tubing
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-21-00-612-043
Servicing of the IDG after Oil Chemical Contamination
AMM 24-21-00-612-804
Servicing of the IDG after Oil Chemical Contamination
AMM 24-21-42-000-802
Removal of the IDG Fuel/Oil Heat-Exchanger
AMM 24-21-42-400-802
Installation of the IDG Fuel/Oil Heat-Exchanger
AMM 24-21-49-000-003
Removal of the IDG Cooling Oil-in Tubes and Hoses
AMM 24-21-49-000-802
AMM 24-21-49-400-003
Installation of the IDG Cooling Oil-in Tubes and Hoses
AMM 24-21-49-400-802
AMM 73-11-60-000-002
Removal of the Integrated Drive Generator (IDG) Oil Cooler Assembly
AMM 73-11-60-400-002
Installation of the Integrated Drive Generator (IDG) Oil Cooler Assembly
3. Fault Confirmation
Subtask 24-21-00-869-057-A ** ON A/C NOT FOR ALL
A. Test
   (1) Not applicable, you cannot confirm this fault on the ground.
4. Fault Isolation
Subtask 24-21-00-810-092-G ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message IDG COOLER 2:
  • smell to make sure there is no fuel in the oil container.
   (1) If you smell fuel in the IDG 2 oil container:
   (2) If there is no sign of fuel in the IDG 2 oil container:
     (a) If the fault continues:
  • do a check and repair the fuel supply of the fuel/oil heat exchanger for a flow that is not sufficient or for a blockage.
       1 If the fault continues:
  • do the trouble shooting for other CFDS messages related to the fuel control circuit.
Subtask 24-21-00-810-092-I ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message IDG COOLER 2:
  • smell to make sure there is no fuel in the oil container.
   (1) If you smell fuel in the IDG 2 oil container:
   (2) If there is no sign of fuel in the IDG 2 oil container:
     (a) If the fault continues:
  • Do a check and repair the fuel supply of the fuel/oil heat exchanger for a flow that is not sufficient or for a blockage.
       1 If the fault continues:
  • Do the trouble shooting for other CFDS messages related to the fuel control circuit.
Subtask 24-21-00-860-067-A ** ON A/C NOT FOR ALL
B. After the subsequent flight, make sure that the fault does not continue.