Failure of the IDG 2 Oil-Out Temperature Bulb or its Wiring
TASK 24-21-00-810-804-A
Failure of the IDG 2 Oil-Out Temperature Bulb or its Wiring
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-21-00-710-056-B ** ON A/C NOT FOR ALL 4. Fault Isolation
[Rev.8 from Aug 2018]
2026.04.04 04:26:29 UTC
Failure of the IDG 2 Oil-Out Temperature Bulb or its Wiring
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242101 | |
| AMM 24-21-51-000-040 | Removal of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-400-040 | Installation of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-22-34-000-001 | Removal of the GCU-1(2) |
| AMM 24-22-34-400-001 | Installation of the GCU-1(2) |
| AMM 24-41-00-740-004 | Operational Check of the GPCU via the CFDS |
Subtask 24-21-00-710-056-B ** ON A/C NOT FOR ALL 4. Fault Isolation
CAUTION:
BEFORE YOU START THE CHECK OF IDG WIRING THAT INCLUDES CONNECTORS, EXAMINE EACH CONNECTOR TO MAKE SURE THAT THERE IS NO CONTAMINATION IN IT.
IF YOU FIND CONTAMINATION, CLEAN THE CONNECTOR AND CONNECT IT AGAIN.
IF THE FAILURE CONTINUES, DO THE TROUBLE SHOOTING PROCEDURE AS GIVEN BELOW.
Subtask 24-21-00-810-053-D ** ON A/C NOT FOR ALL A. If the test gives the maintenance message CHECK GCU2 PIN A8A, A9B ; IDG2 B7, B8 WIRING:
Subtask 24-21-00-710-057-B ** ON A/C NOT FOR ALL - do a check of the wiring for open circuit or short to ground between respectively the IDG 2 pins B/7, B/8 and the GCU 2 pins A/8A, A/9B ASM 242101.
- repair it.
- do a check of the resistance between the pins B/7 and B/8 of the IDG 2.
NOTE: The normal value is 99.1 Ohms plus or minus 5 Ohms at 25°C.
(a) If the resistance value is out of the specified limits: - replace the IDG [4000XU] AMM 24-21-51-000-040 and AMM 24-21-51-400-040.
- replace the GCU-2 [1XU2] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
B. Do the test given in Para. 3.