Unwanted IDG2 Disconnection Message
TASK 24-20-00-810-968-A
Unwanted IDG2 Disconnection Message
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-869-126-A
Subtask 24-20-00-810-243-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:29 UTC
Unwanted IDG2 Disconnection Message
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242101 |
Subtask 24-20-00-869-126-A
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 24-20-00-810-243-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message IDG2 DISCONNECTED:
Subtask 24-20-00-810-243-B ** ON A/C NOT FOR ALL - Do a check of the wiring ASM 242101 between:
. Pin A/X2 of the IDG 2 DISC CTL relay (4XT) and the ground
. Pin A/X1 of the IDG 2 DISC CTL relay (4XT) and the pin A/B2 of the relay (8XT)
. Pin A/B3 of the relay (8XT) and the pin A/B1 of the ELEC/IDG 2 pushbutton switch (6XT).
- Repair the wiring .
- Replace the RELAY-IDG 2 DISC CTL [4XT] .
- Replace the
RELAY (8XT) .
- Replace the P/BSW-ELEC/IDG 2 [6XT] .
A. If the fault symptom is identified by the CFDS message IDG2 (E2-4000XU) MANUAL DISCONNECT:
- Do a check of the wiring ASM 242101 between:
. Pin A/X2 of the IDG 2 DISC CTL relay (4XT) and the ground
. Pin A/X1 of the IDG 2 DISC CTL relay (4XT) and the pin A/B2 of the relay (8XT)
. Pin A/B3 of the relay (8XT) and the pin A/B1 of the ELEC/IDG 2 pushbutton switch (6XT).
- Repair the wiring .
- Replace the RELAY-IDG 2 DISC CTL [4XT] .
- Replace the
RELAY (8XT) .
- Replace the P/BSW-ELEC/IDG 2 [6XT] .