Failure of the Auxiliary Power Unit Generator
TASK 24-20-00-810-948-A
Failure of the Auxiliary Power Unit Generator
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-710-143-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-180-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:26 UTC
Failure of the Auxiliary Power Unit Generator
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 24-41-34-000-001 | Removal of the Ground Power Control Unit (GPCU) |
| AMM 24-41-34-400-001 | Installation of the Ground Power Control Unit (GPCU) |
Subtask 24-20-00-710-143-A ** ON A/C NOT FOR ALL
A. Test
4. Fault IsolationNOTE: This CFDS message comes into view when there is an overfrequency trip condition of the APU generator related to an overspeed condition of the turbine. The CFDS message ECB (59KD)/APU (4005KM)/GAPCU (24XG) can come into view with CMS messages related to the chapter 49 or to the ECB. Do the trouble shooting procedure related to the chapter 49 or to the ECB messages before you do the trouble shooting for the CFDS message ECB (59KD)/APU (4005KM)/GAPCU (24XG).
(1) If the CFDS message ECB (59KD)APU (4005KM)/GAPCU (24XG) comes into view with CFDS messages related to the chapter 49 or to the ECB: - do the trouble shooting procedure related to the chapter 49 or ECB messages.
- do the trouble shooting given in Para 4.A.
Subtask 24-20-00-810-180-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message ECB (59KD)/APU (4005KM)/GAPCU (24XG) and the upper ECAM-DU warning APU GEN FAULT:
Subtask 24-20-00-860-173-A ** ON A/C NOT FOR ALL - replace the GAPCU [24XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
B. Make sure that the aircraft electrical circuits operate correctly in APU configuration.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) Let the APU generator operate for five minutes to make sure that it operates correctly.
(3) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) Let the APU generator operate for five minutes to make sure that it operates correctly.
(3) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.