Failure of the Signal from the APU Control Relay to the GAPCU
TASK 24-20-00-810-947-A
Failure of the Signal from the APU Control Relay to the GAPCU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-740-086-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-176-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:26 UTC
Failure of the Signal from the APU Control Relay to the GAPCU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242202 | |
| ASM 242302 | |
| AMM 24-41-00-740-002 | Operational Check of the GAPCU via the CFDS |
| AMM 24-41-34-000-001 | Removal of the Ground Power Control Unit (GPCU) |
| AMM 24-41-34-400-001 | Installation of the Ground Power Control Unit (GPCU) |
| ASM 496101 |
Subtask 24-20-00-740-086-A ** ON A/C NOT FOR ALL
A. Test
(1) If the CFDS message APU CTL RLY (6KD)/ECB (59KD)/GAPCU (24XG) comes into view with CFDS messages related to the chapter 49 or to the ECB:
4. Fault Isolation(1) If the CFDS message APU CTL RLY (6KD)/ECB (59KD)/GAPCU (24XG) comes into view with CFDS messages related to the chapter 49 or to the ECB:
- do the trouble shooting procedure related to the chapter 49 or ECB messages.
- do the BITE test of the GAPCU AMM 24-41-00-740-002.
- do the trouble shooting given in Para 4.A.
- do the trouble shooting given in Para 4.B.
Subtask 24-20-00-810-176-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the message TEST FAILED:
Subtask 24-20-00-865-055-A ** ON A/C NOT FOR ALL - push the line key adjacent to the TEST FAILED message.
- replace the GAPCU [24XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
B. Table of the circuit breakers used in this procedure:
Subtask 24-20-00-810-177-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | ELEC/GEN1/OFF/BTC1 SPLY | 5XU | T28 |
C. If the BITE test gives the message TEST PASSED:
Subtask 24-20-00-810-177-C ** ON A/C NOT FOR ALL - Do a check of the wiring of the APU ready circuit ASM 496101, ASM 242302 and ASM 242202 between:
. Pin AB/6J of the ECB (59KD) and pin A/X1 of the APU AVAIL relay (6KD)
. Pin A/X2 of the APU AVAIL relay (6KD) and ground
. Pin AA/7C of the GAPCU (24XG) and pin A/A1 of the APU AVAIL relay (6KD)
. Pin A/A2 of the APU AVAIL relay (6KD) and pin A/37 of diode module 1162VD
. Pin A/38 of diode module 1162VD and pin 2 of the ELEC/GEN1/OFF/BTC1 SPLY circuit breaker (5XU).
- Repair or replace as necessary.
- Replace RELAY-APU AVAIL [6KD] .
- Do a check for 28VDC at pin A/38 of diode module 1162VD.
- Do a check and repair the wiring between pin 2 of the ELEC/GEN1/OFF/BTC1 SPLY circuit breaker (5XU) and pin A/38 of diode module 1162VD ASM 242202.
- Replace diode module 1162VD , and
- Replace GAPCU [24XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
C. If the BITE test gives the message TEST PASSED:
Subtask 24-20-00-740-087-A ** ON A/C NOT FOR ALL - Do a check of the wiring of the APU ready circuit, ASM 496101, ASM 242302 and ASM 242202, between:
. Pin AB/10J of the GAPCU and pin C3 of the ELEC/APU GEN pushbutton switch (2XS)
. Pin C1 of the ELEC/APU GEN pushbutton switch (2XS) and pin X1 of the APU-GLC auxiliary control-relay (4XS)
. Pin X2 of the APU-GLC auxiliary control-relay (4XS) and the ground
. Pin AB/10J of the GAPCU and pin A/1 of the APU-GLC auxiliary control-relay (4XS)
. Pin AB/6J of the ECB (59KD) and pin A/X1 of the APU AVAIL relay (6KD)
. Pin A/X2 of the APU AVAIL relay (6KD) and the ground
. Pin AA/7C of the GAPCU (24XG) and pin A/A1 of the APU AVAIL relay (6KD)
. Pin A/A2 of the APU AVAIL relay (6KD) and pin A/2 of the APU-GLC auxiliary control-relay (4XS)
. Pin A/3 of the APU-GLC auxiliary control-relay (4XS) and pin 2 of the ELEC/GEN1/OFF/BTC1 SPLY circuit breaker (5XU).
- Repair it.
- Replace the RELAY-APU AVAIL [6KD] .
- Replace the RELAY-APU GLC AUX CTL [4XS] .
- Replace the GAPCU [24XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
D. Do the test given in Para. 3.