Overload on the Electrical Network of the Generator 1
TASK 24-20-00-810-918-A
Overload on the Electrical Network of the Generator 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-860-180-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-865-062-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-860-162-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:39:02 UTC
Overload on the Electrical Network of the Generator 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| ASM 245102 | |
| AMM 71-00-00-710-003 | Engine Automatic Start |
| AMM 71-00-00-710-028 | Engine Shutdown |
| AMM 71-00-00-710-043 | Normal Engine Automatic Start Procedure |
| AMM 71-00-00-860-814 | Shutdown of the Engine |
| AMM 71-00-00-860-823 | Start the Engine (Normal Automatic Start) |
Subtask 24-20-00-860-180-A ** ON A/C NOT FOR ALL
A. Job Set-up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits from the external power AMM 24-41-00-861-002.
(2) On the ELEC panel 35VU, make sure that the ELEC/GEN 1 pushbutton switch (3XU1) is pushed.
(3) On the ELEC panel 35VU, make sure that the ELEC/GALLEY pushbutton switch (2XA) is pushed (the OFF legend is off).
Subtask 24-20-00-700-119-B ** ON A/C NOT FOR ALL (1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits from the external power AMM 24-41-00-861-002.
(2) On the ELEC panel 35VU, make sure that the ELEC/GEN 1 pushbutton switch (3XU1) is pushed.
(3) On the ELEC panel 35VU, make sure that the ELEC/GALLEY pushbutton switch (2XA) is pushed (the OFF legend is off).
B. Test
(1) Start the engine 1 AMM 71-00-00-710-003.
(2) On the upper ECAM DU, the warning GEN 1 OVERLOAD is shown.
4. Fault Isolation(1) Start the engine 1 AMM 71-00-00-710-003.
(2) On the upper ECAM DU, the warning GEN 1 OVERLOAD is shown.
Subtask 24-20-00-865-062-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 24-20-00-810-208-F ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 123VU | BUS 1/131XP-A/SPLY | 5XN1 | AB12 |
| 123VU | BUS 1/103XP/SPLY | 3XN1 | AB11 |
| 123VU | TR1/SPLY | 2PU1 | AB10 |
| 123VU | B HYD/ELEC PUMP | 2701GJ | AB09 |
| 123VU | AC ESS/BUS ON/BUS 1 | 1XC | AC12 |
| 123VU | BUS 1/101XP/SPLY | 1XN1 | AD11 |
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
| 123VU | BUS 1/110XP/SPLY | 7XN1 | AF11 |
| 123VU | ANTI ICE/L/WHSLD | 1DG1 | AF10 |
B. If the test confirms the fault:
(2) If the circuit breakers 1MC and 12MC are closed:
Subtask 24-20-00-810-208-G ** ON A/C NOT FOR ALL - in the AC power center panel 123VU, do a check of the circuit breakers 1MC and 12MC.
(2) If the circuit breakers 1MC and 12MC are closed:
- on the AC power center panel 123VU, do a check of the status of the circuit breakers 5XN1, 3XN1, 7XN1, 1DG1, 1XC, 2701GJ, 1HQ, 1XN1 and 2PU1.
- do a check of the loads downstream of the open circuit breaker(s) for a short to ground or a defective component.
- stop the engine 1 AMM 71-00-00-710-003
- de-energize the aircraft electrical network from the external power AMM 24-41-00-862-002 and do the procedure that follows.
B. If the test confirms the fault:
(2) If the circuit breakers 1MC and 12MC are closed:
Subtask 24-20-00-810-209-D ** ON A/C NOT FOR ALL - In the AC power center panel 123VU, do a check of the circuit breakers 1MC and 12MC.
(2) If the circuit breakers 1MC and 12MC are closed:
- On the AC power center panel 123VU, do a check of the status of the circuit breakers 5XN1, 3XN1, 7XN1, 1DG1, 1XC, 2701GJ, 1HQ, 1XN1 and 2PU1.
- Do a check of the loads downstream of the open circuit breaker(s) for a short to ground or a defective component.
- Stop the IDG-ENG 1 [4000XU1] AMM 71-00-00-860-814
- De-energize the aircraft electrical network from the external power AMM 24-41-00-862-002 and do the procedure that follows.
C. Do a check of the AC/DC main power center 120VU:
Subtask 24-20-00-710-137-B ** ON A/C NOT FOR ALL - Open the AC/DC main power center 120VU and do a check of the wiring for a short circuit or a short to ground between downstream of the GLC 1 (load side) and the loads ASM 245102.
- Repair or replace as necessary.
- Do a check of the feeders for a short to ground, a short circuit or a related defective equipement between the pins 4, 5 and 6 of the generator 1 contactor module (30XN1) and the load side ASM 245102.
- Repair or replace as necessary.
- Energize the aircraft electrical network from the external power AMM 24-41-00-861-002.
- Start the engine 1 only AMM 71-00-00-710-043 and close one by one the circuit breakers until the warning GEN 1 OVERLOAD is shown. Repair the wiring or the component of the defective circuit.
D. Do this test to make sure that the failure is repaired:
(1) Make sure that the circuit breakers are closed (if the circuit breakers are not closed, close them).
(2) Energize the aircraft electrical circuit from the external power AMM 24-41-00-861-002.
(3) On the ELEC panel 35VU, make sure that the ELEC/GALLEY pushbutton switch is pushed.
(4) Start engine 1 AMM 71-00-00-860-823.
(5) After five minutes, make sure that, on the upper ECAM DU, the warning GEN 1 OVERLOAD is not shown.
(6) Stop engine 1 AMM 71-00-00-860-814.
Subtask 24-20-00-710-137-F ** ON A/C NOT FOR ALL (1) Make sure that the circuit breakers are closed (if the circuit breakers are not closed, close them).
(2) Energize the aircraft electrical circuit from the external power AMM 24-41-00-861-002.
(3) On the ELEC panel 35VU, make sure that the ELEC/GALLEY pushbutton switch is pushed.
(4) Start engine 1 AMM 71-00-00-860-823.
(5) After five minutes, make sure that, on the upper ECAM DU, the warning GEN 1 OVERLOAD is not shown.
(6) Stop engine 1 AMM 71-00-00-860-814.
D. Do this test to make sure that the failure is repaired:
(1) Make sure that the circuit breakers are closed (if the circuit breakers are not closed, close them).
(2) Energize the aircraft electrical circuit from the external power A AMM 24-41-00-861-002.
(3) On the ELEC panel 35VU, make sure that the ELEC/GALLEY pushbutton switch is pushed.
(4) Start the engine 1 AMM 71-00-00-710-003.
(5) After five minutes, make sure that, on the upper ECAM DU, the warning GEN 1 OVERLOAD is not shown.
(6) Stop the engine 1 AMM 71-00-00-710-028.
5. Close-up(1) Make sure that the circuit breakers are closed (if the circuit breakers are not closed, close them).
(2) Energize the aircraft electrical circuit from the external power A AMM 24-41-00-861-002.
(3) On the ELEC panel 35VU, make sure that the ELEC/GALLEY pushbutton switch is pushed.
(4) Start the engine 1 AMM 71-00-00-710-003.
(5) After five minutes, make sure that, on the upper ECAM DU, the warning GEN 1 OVERLOAD is not shown.
(6) Stop the engine 1 AMM 71-00-00-710-028.
Subtask 24-20-00-860-162-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) De-energize the aircraft electrical circuits from the external power AMM 24-41-00-862-002.
(1) De-energize the aircraft electrical circuits from the external power AMM 24-41-00-862-002.