W DOC AIRBUS | TSM A320F

Failure of the GLC 2 Contacts in the Closed Position


TASK 24-20-00-810-895-A
Failure of the GLC 2 Contacts in the Closed Position


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-22-55-000-001
Removal of the Contactors
AMM 24-22-55-400-002
Installation of the Contactors
AMM 24-41-00-740-002
Operational Check of the GAPCU via the CFDS
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
AMM 31-60-00-860-001
EIS Start Procedure
AMM 31-60-00-860-002
EIS Stop Procedure
AMM 71-00-00-710-003
Engine Automatic Start
AMM 71-00-00-710-028
Engine Shutdown
AMM 71-00-00-860-814
Shutdown of the Engine
AMM 71-00-00-860-823
Start the Engine (Normal Automatic Start)
3. Fault Confirmation
Subtask 24-20-00-869-073-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
NOTE: As the GEN 2 was set to OFF because of a true failure, the fault confirmation is not necessary.
4. Fault Isolation
Subtask 24-20-00-810-140-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message GLC2 (9XU2) and the upper ECAM-DU warnings GEN 2 FAULT and AC BUS 2 FAULT:
Subtask 24-20-00-710-118-C ** ON A/C NOT FOR ALL
B. Do this operational test to make sure that the system operates correctly.
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
     (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
   (2) In the cockpit, on the ELEC panel 35VU:
  • Push, release and push again the GEN 2 pushbutton switch (3XU2).
   (3) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
   (4) Start engine 2 AMM 71-00-00-860-823.
   (5) Do this test:
ACTION
RESULT
On the ECAM control panel:
  • Push the ELEC key to get the ELEC page.
On the lower ECAM DU:
  • The correct electrical parameters of GEN 2 are shown and GEN 2 supplies the AC2 busbar.
Subtask 24-20-00-710-118-G ** ON A/C NOT FOR ALL
B. Do this operational test to make sure that the system operates correctly.
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
     (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
   (2) On the ELEC panel 35VU:
  • push, release and push again the GEN 2 pushbutton switch (3XU2).
   (3) Do the operational test of the GAPCU AMM 24-41-00-740-002.
   (4) Start the engine 2 AMM 71-00-00-710-003.
   (5) Do this test:
ACTION
RESULT
On the ECAM control panel:
  • get the ELEC page.
On the lower ECAM DU:
  • the correct electrical parameters of the GEN 2 are shown and the AC2 busbar is supplied by the GEN 2.
5. Close-up
Subtask 24-20-00-860-143-C ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Stop engine 2 AMM 71-00-00-860-814.
   (2) Do the EIS stop procedure
AMM 31-60-00-860-002.
   (3) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
   (4) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
Subtask 24-20-00-860-143-G ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Stop the engine 2 AMM 71-00-00-710-028.
   (2) Do the EIS stop procedure
AMM 31-60-00-860-002.
   (3) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
   (4) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
[Rev.8 from Aug 2018] 2026.04.04 04:26:19 UTC