Failure of the GCU 2 Air/Ground Status


TASK 24-20-00-810-879-A
Failure of the GCU 2 Air/Ground Status


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 242201
AMM 24-22-34-000-001
Removal of the GCU-1(2)
AMM 24-22-34-400-001
Installation of the GCU-1(2)
AMM 24-41-00-740-002
Operational Check of the GAPCU via the CFDS
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
3. Fault Confirmation
Subtask 24-20-00-740-072-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
     (a) If the BITE test gives the message TEST FAILED:
  • Do the trouble shooting given in Para 4.B.
     (b) If the BITE test gives the message TEST PASSED:
  • Do the trouble shooting given in Para 4.C.
4. Fault Isolation
Subtask 24-20-00-865-067-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
49VUFWS/FWC1/SPLY3WWF01
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
121VUEIS/FWC2/SPLY2WWQ07
Subtask 24-20-00-810-193-A ** ON A/C NOT FOR ALL
B. If the BITE test gives the message TEST FAILED:
  • push the line key adjacent to the TEST FAILED message.
   (1) If the maintenance message GCU2 (1XU2) comes into view with AC GEN maintenance status:
NOTE: The AC GEN maintenance status can appear during ATA 32 maintenance action. To make sure that it is an unwanted warning, do the steps that follow to do a reset of the LGCIU 1(2) and FWC 1(2) to clear the warning.
     (a) Open circuit breakers 52GA, 1GA and 2GA.
  • Wait for 30 seconds and make sure that on the upper ECAM display unit and STATUS pages, fault warnings come into view.
     (b) Open circuit breakers 3WW and 2WW.
  • Wait for 30 seconds.
     (c) Close circuit breakers 52GA, 1GA and 2GA.
  • Wait for 30 seconds.
     (d) Close circuit breakers 3WW and 2WW.
  • Make sure that the AC GEN maintenance status is no longer shown on the upper ECAM display unit.
  • If the AC GEN maintenance status continues to be shown, replace the GCU-2 [1XU2] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
   (2) If the maintenance message GCU2 (1XU2) comes into view without AC GEN maintenance status:
Subtask 24-20-00-810-167-A ** ON A/C NOT FOR ALL
C. If the BITE test gives the message TEST PASSED:
   (1) Do the trouble shooting for chapter-32 CFDS messages related to the LGCIU 1.
   (2) If there are no CFDS messages related to the LGCIU 1:
  • do a check of the ground/flight status wiring for a short circuit or a short to ground between pin A/2C of the GCU 2 and pin B/10H of the LGCIU 1 (5GA1) ASM 242201.
     (a) If there is no continuity:
  • repair or replace as necessary.
     (b) If there is continuity:
       1 If the fault continues:
Subtask 24-20-00-740-073-A ** ON A/C NOT FOR ALL
D. Do the test given in Para. 3.