Failure of the GCU 1 Air/Ground Status
TASK 24-20-00-810-878-A
Failure of the GCU 1 Air/Ground Status
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-740-070-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-865-066-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:17 UTC
Failure of the GCU 1 Air/Ground Status
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242201 | |
| AMM 24-22-34-000-001 | Removal of the GCU-1(2) |
| AMM 24-22-34-400-001 | Installation of the GCU-1(2) |
| AMM 24-41-00-740-002 | Operational Check of the GAPCU via the CFDS |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
Subtask 24-20-00-740-070-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
(a) If the BITE test gives the message TEST FAILED:
4. Fault Isolation(1) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
(a) If the BITE test gives the message TEST FAILED:
- do the trouble shooting given in Para 4.B.
- do the trouble shooting given in Para 4.C.
Subtask 24-20-00-865-066-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 24-20-00-810-192-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| 49VU | FWS/FWC1/SPLY | 3WW | F01 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | HYDRAULIC/LGCIU/SYS1/GRND SPLY | 52GA | Q34 |
| 121VU | EIS/FWC2/SPLY | 2WW | Q07 |
B. If the BITE test gives the message TEST FAILED:
Subtask 24-20-00-810-166-A ** ON A/C NOT FOR ALL - push the line key adjacent to the TEST FAILED message.
NOTE: The AC GEN maintenance status can appear during ATA 32 maintenance action. To make sure that it is an unwanted warning, do the steps that follow to do a reset of the LGCIU 1(2) and FWC 1(2) to clear the warning.
(a) Open circuit breakers 52GA, 1GA and 2GA. - Wait for 30 seconds and make sure that on the upper ECAM display unit and STATUS pages, fault warnings come into view.
- Wait for 30 seconds.
- Wait for 30 seconds.
- Make sure that the AC GEN maintenance status is no longer shown on the upper ECAM display unit.
- If the AC GEN maintenance status continues to be shown, replace the GCU-1 [1XU1] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
- replace the GCU-1 [1XU1] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
C. If the BITE test gives the message TEST PASSED:
(1) Do the trouble shooting for chapter-32 CFDS messages related to the LGCIU 1.
(2) If there are no CFDS messages related to the LGCIU 1:
Subtask 24-20-00-740-071-A ** ON A/C NOT FOR ALL (1) Do the trouble shooting for chapter-32 CFDS messages related to the LGCIU 1.
(2) If there are no CFDS messages related to the LGCIU 1:
- do a check of the ground/flight status wiring for a short circuit or a short to ground between pin A/2C of the GCU 1 and pin B/9E of the LGCIU 1 (5GA1) ASM 242201.
- repair or replace as necessary.
- replace the GCU-1 [1XU1] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
- replace the LGCIU-1 [5GA1] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
D. Do the test given in Para. 3.