Failure of the Generator Control Unit 2
TASK 24-20-00-810-871-A
Failure of the Generator Control Unit 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-740-060-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-128-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:16 UTC
Failure of the Generator Control Unit 2
1. Possible Causes
- GCU-2 [1XU2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242203 | |
| AMM 24-22-34-000-001 | Removal of the GCU-1(2) |
| AMM 24-22-34-400-001 | Installation of the GCU-1(2) |
| AMM 24-41-00-740-002 | Operational Check of the GAPCU via the CFDS |
Subtask 24-20-00-740-060-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
(a) If the BITE test gives the message TEST FAILED:
4. Fault Isolation(1) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
(a) If the BITE test gives the message TEST FAILED:
- do the trouble shooting given in Para 4.A.
- stop the trouble shooting.
Subtask 24-20-00-810-128-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the message TEST FAILED:
Subtask 24-20-00-740-061-A ** ON A/C NOT FOR ALL - push the line key adjacent to the TEST FAILED message.
- replace the GCU-2 [1XU2] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
- do a check and repair the wiring between the GCU 2 and the GLC 2 auxiliary control relay (4XU2) ASM 242203 for a short to 28VDC between:
. pin B/10J of the GCU 2 and pin A/C3 of the ELEC/GEN 2 pushbutton switch (3XU2)
. pin A/C1 of the ELEC/GEN 2 pushbutton switch and pin A/X1 of the GLC 2 auxiliary control relay.
B. Do the test given in Para. 3.