Failure of the ENG/APU FIRE Panel or its Wiring to the GCU 2


TASK 24-20-00-810-867-A
Failure of the ENG/APU FIRE Panel or its Wiring to the GCU 2


1. Possible Causes
  • GCU-2 [1XU2]
  • ENG/APU FIRE PNL [1WD]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 242203
AMM 24-22-34-000-001
Removal of the GCU-1(2)
AMM 24-22-34-400-001
Installation of the GCU-1(2)
AMM 24-41-00-740-002
Operational Check of the GAPCU via the CFDS
AMM 26-12-12-000-001
Removal of the ENG/APU Fire Panel
AMM 26-12-12-400-001
Installation of the ENG/APU Fire Panel
3. Fault Confirmation
Subtask 24-20-00-740-102-A ** ON A/C NOT FOR ALL
A. Test
NOTE: It is not necessary to do the trouble shooting for the CFDS message ENG2 FIRE PB SW (1WD)/ GCU2 (1XU2) if the flight or maintenance log books show that the flight crew or the maintenance personnel pushed the ENG 2 FIRE pushbutton switch on the ENG/APU FIRE panel after an engine-fire condition or to do a test of the engine fire loop.
To remove this CFDS message at the start of the subsequent flight, release and push the ELEC/GEN 2 pushbutton switch (2XU2) before the subsequent engine start sequence.
If the flight or maintenance crew did not push the ENG 2 FIRE pushbutton switch, the trip was accidental and you must do the trouble shooting procedure that follows:
   (1) If the BITE test gives the message TEST FAILED:
  • do the trouble shooting given in Para 4.A.
   (2) If the BITE test gives the message TEST PASSED:
  • do the trouble shooting given in Para 4.B.
4. Fault Isolation
Subtask 24-20-00-810-216-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the message TEST FAILED:
  • push the line key adjacent to the TEST FAILED message.
   (1) If the maintenance message GCU2 (1XU2) comes into view:
Subtask 24-20-00-810-110-A ** ON A/C NOT FOR ALL
B. If the BITE test gives the message TEST PASSED:
  • do a check of the contact of the ENG/APU FIRE panel (1WD) for a correct operation between pin C/U and pin C/V ASM 242203.
   (1) If the contact operation is not correct:
   (2) If the contact operation is correct:
  • do a check of the wiring for open circuit or short to ground between pin C/V of the ENG/APU FIRE panel and pin A/3J of the GCU 2 ASM 242203.
     (a) If the wiring is not correct:
  • repair or replace as necessary.
     (b) If the wiring is correct:
Subtask 24-20-00-740-103-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:16 UTC