W DOC AIRBUS | TSM A320F

Overcurrent of the GEN 2 Because of a Failure of the BTC 2 Control Circuit


TASK 24-20-00-810-861-A
Overcurrent of the GEN 2 Because of a Failure of the BTC 2 Control Circuit


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-20-00-810-889-A
Failure of an Opposite Channel of the Generator 2 Channel
ASM 242203
AMM 24-22-34-000-001
Removal of the GCU-1(2)
AMM 24-22-34-400-001
Installation of the GCU-1(2)
AMM 24-22-55-000-001
Removal of the Contactors
AMM 24-22-55-400-002
Installation of the Contactors
AMM 24-41-00-740-002
Operational Check of the GAPCU via the CFDS
3. Fault Confirmation
Subtask 24-20-00-740-063-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
     (a) If the BITE test gives the message TEST FAILED:
  • do the trouble shooting given in Para 4.A.
     (b) If the BITE test gives the message TEST PASSED:
  • do the trouble shooting given in Para 4.B.
4. Fault Isolation
Subtask 24-20-00-810-134-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the message TEST FAILED:
  • push the line key adjacent to the TEST FAILED message.
   (1) If the maintenance message GCU2 (1XU2) comes into view:
Subtask 24-20-00-810-201-A ** ON A/C NOT FOR ALL
B. If the BITE test gives the message TEST PASSED:
   (1) Do the trouble shooting for a delta current condition of the IDG 2 (Ref. TSM TASK 24-20-00-810-889).
   (2) If the fault continues:
  • do a check of the coil return wiring for a short circuit or a short to ground between pin B/5 of the BTC 2 and pin A/9A of the GCU 2 ASM 242203.
     (a) If the wiring is not correct:
  • repair or replace as necessary.
     (b) If the wiring is correct:
  • do a check of the auxiliary contacts for correct operation between pin B/29 and pin B/27 of the BTC 2 ASM 242203.
       1 If there is no continuity:
       2 If there is continuity:
  • do a check of the wiring for an open circuit condition between pin B/29 of the BTC 2 and pin A/4C of the GCU 2 ASM 242203.
         a If the wiring is not correct:
  • repair or replace as necessary.
         b If the wiring is correct:
Subtask 24-20-00-740-097-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:15 UTC