Loss of the ECAM and EFIS Displays during Engine Start at IDG 2 Connection
TASK 24-20-00-810-859-A
Loss of the ECAM and EFIS Displays during Engine Start at IDG 2 Connection
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-710-095-B ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-106-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:15 UTC
Loss of the ECAM and EFIS Displays during Engine Start at IDG 2 Connection
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-21-51-000-040 | Removal of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-000-803 | Removal of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-400-040 | Installation of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-400-803 | Installation of the Integrated Drive Generator - IDG 1(2) |
| AMM 71-00-00-710-003 | Engine Automatic Start |
| AMM 71-00-00-860-823 | Start the Engine (Normal Automatic Start) |
Subtask 24-20-00-710-095-B ** ON A/C NOT FOR ALL
A. Test
(1) Start the engine 2 AMM 71-00-00-710-003.
(2) The fault is confirmed if during the engine start:
Subtask 24-20-00-710-095-F ** ON A/C NOT FOR ALL (1) Start the engine 2 AMM 71-00-00-710-003.
(2) The fault is confirmed if during the engine start:
- the ECAM and EFIS display units go blank with a diagonal line for more than one second,
- and the IDG 2 is connected below 50 % N2.
A. Test
(1) Start engine 2 AMM 71-00-00-860-823.
(2) The fault is confirmed if, during the engine start:
4. Fault Isolation(1) Start engine 2 AMM 71-00-00-860-823.
(2) The fault is confirmed if, during the engine start:
- The ECAM DU and EFIS DU show only a diagonal line for more than one second, and IDG 1 connects at less than 55% N2.
Subtask 24-20-00-810-106-B ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
Subtask 24-20-00-810-106-F ** ON A/C NOT FOR ALL - do a check of the resistance of the IDG 2 MPU coil between pin B/1 and pin B/2 (17.5 ohms plus or minus 3.5 ohms at 25 deg.C (77 deg.F)).
- replace the IDG [4000XU] AMM 24-21-51-000-040 and AMM 24-21-51-400-040.
A. If the test confirms the fault:
Subtask 24-20-00-710-096-A ** ON A/C NOT FOR ALL - Do a check of the resistance of the IDG 2 MPU coil between pin B/1 and pin B/2 (17.5 ohms plus or minus 3.5 ohms at 25 deg.C (77 deg.F)).
- Replace IDG-ENG 2 [4000XU2] AMM 24-21-51-000-803 and AMM 24-21-51-400-803.
B. Do the test given in Para. 3.A.