Failure of the IDG2 Disconnect Circuit
TASK 24-20-00-810-852-A
Failure of the IDG2 Disconnect Circuit
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-700-101-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-090-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:14 UTC
Failure of the IDG2 Disconnect Circuit
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-21-00-720-041 | Operational Test of the IDG Disconnect and Reconnect (Reset) Function - Engine in Operation |
| ASM 242101 | |
| AMM 24-21-51-000-040 | Removal of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-400-040 | Installation of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-22-34-000-001 | Removal of the GCU-1(2) |
| AMM 24-22-34-400-001 | Installation of the GCU-1(2) |
Subtask 24-20-00-700-101-A ** ON A/C NOT FOR ALL
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 24-20-00-810-090-B ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message: CHECK IDG2 DISCONNECT CKT and by the warnings IDG2 OIL LO PR and IDG2 OIL OVHT on the upper ECAM display unit:
Subtask 24-20-00-720-051-B ** ON A/C NOT FOR ALL - replace the GCU-2 [1XU2] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
- replace the RELAY-IDG 2 DISC CTL [4XT] .
- replace the
RELAY-FUNCTION (8XT) .
- do a check of the IDG2 disconnect wiring between:
the pin 2 of the circuit breaker (2XT) and the pin B3 of the ELEC/IDG2 pushbutton switch (6XT)
the pin 2 of the circuit breaker (2XT) and the pin A2 of the relay (4XT)
the pin B1 of the ELEC/IDG2 pushbutton switch (6XT) and the pin X1 of the relay (8XT)
the pin A1 of the relay (4XT) and successively the pin A/3B of the GCU2 (1XU2) and the pin A/12 of the IDG2 (4000XU)
the pins B2 and X2 of the relay (4XT) and the ground
the pin A/13 of the IDG2 (4000XU) and the ground
the pin A/14 of the IDG2 (4000XU) and the pin A/6B of the EGIU2 (22XU2)
the pin B1 of the relay (4XT) and the pin A/4B of the EGIU2 (22XU2) ASM 242101.
- repair it.
- do a check of the resistance between the IDG2 disconnect solenoid and disconnect switch:
between the pins A/12 and A/13 of the solenoid (normal resistance = 5 ohms plus or minus 2.5 ohms at 25°C)
between the pins A/14 and A/13 of the switch (open circuit when the IDG is not disconnected, and closed circuit when the IDG is disconnected).
- replace the IDG [4000XU] AMM 24-21-51-000-040 and AMM 24-21-51-400-040.