Failure of the APU Generator PMG
TASK 24-20-00-810-842-A
Failure of the APU Generator PMG
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-700-088-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-081-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:13 UTC
Failure of the APU Generator PMG
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242301 | |
| AMM 24-23-34-000-001 | Removal of the GCU-APU |
| AMM 24-23-34-400-001 | Installation of the GCU-APU |
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
Subtask 24-20-00-700-088-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
4. Fault IsolationNot applicable.
NOTE: As the APU GEN was set to OFF because of a true failure, the fault confirmation is not necessary.
Subtask 24-20-00-810-081-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message CHECK GCU APU PIN C2 TO C4 GEN APU PIN A12 TO A14 and the upper ECAM DU warning APU GEN FAULT:
Subtask 24-20-00-700-089-A ** ON A/C NOT FOR ALL - Do a check of the wiring for open circuit or short to ground between respectively the APU GEN pins A/12, A/13, A/14 and the APU GCU pins C/2, C/3, C/4 ASM 242301.
- repair it.
- Do an impedance check of the APU generator PMG stator, between successively 2 among the 3 pins A/12, A/13 and A/14, then do a check for open circuit between the APU generator pins A/12, A/13, A/14 and the case.
NOTE: The normal impedance between 2 pins is 0.868 ohms plus or minus 0.156 ohms at 20°C.
(a) If the values are out of the specified limits: - replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- replace the GCU-APU [1XS] AMM 24-23-34-000-001 and AMM 24-23-34-400-001.
B. Make sure that the aircraft electrical circuits operate correctly in APU configuration.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.