Failure of the APU Feeder
TASK 24-20-00-810-841-A
Failure of the APU Feeder
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-700-086-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-080-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:13 UTC
Failure of the APU Feeder
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242301 | |
| AMM 24-23-34-000-001 | Removal of the GCU-APU |
| AMM 24-23-34-400-001 | Installation of the GCU-APU |
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
Subtask 24-20-00-700-086-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
4. Fault IsolationNot applicable.
NOTE: As the APU GEN was set to OFF because of a true failure, the fault confirmation is not necessary.
Subtask 24-20-00-810-080-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message CHECK GLC APU PIN D, E, F GCU APU PIN B1A, B2B, B3A and the upper ECAM DU warning : APU GEN FAULT:
Subtask 24-20-00-810-080-B ** ON A/C NOT FOR ALL - do a check of the wiring :
. between respectively the APU GCU pins B/1A, B/2B, B/3A and the APU GLC pins F, E, D
. then between respectively the APU GEN terminals T/1, T/2, T/3 and the APU GLC pins F, E, D ASM 242301.
- repair it.
- do an impedance check of the APU generator stator between terminals T/1, T/2, T/3 and terminal N.
NOTE: The normal impedance between each terminal and the neutral is 9.35 m.ohms plus or minus 1.25 m.ohms at 25°C.
(a) If the impedance is in the specified limits: - make sure that the pins T/1, T/2, T/3 are electrically insulated from the case
- then, after you have removed the neutral lead, do a check of the pins T/1, T/2 or T/3 for short to ground.
- replace the GCU-APU [1XS] AMM 24-23-34-000-001 and AMM 24-23-34-400-001.
NOTE: Do not remove the APU GCU before you do the other steps of the trouble shooting.
2 If not insulated: - replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
A. If the fault symptom is identified by the CFDS message CHECK GLC APU PIN D, E, F GCU APU PIN B1A, B2B, B3A and the upper ECAM DU warning APU GEN FAULT:
Subtask 24-20-00-700-087-A ** ON A/C NOT FOR ALL - do a check of the wiring between:
. respectively the APU GCU pins B/1A, B/2B, B/3A and the APU/EXT power contactor module (29XN) pins 7, 8, 9.
. then respectively the APU GEN terminals T/1, T/2, T/3 and the APU/EXT power contactor module (29XN) pins 7, 8, 9 ASM 242301.
- repair it.
- do an impedance check of the APU generator stator between terminals T/1, T/2, T/3 and terminal N.
NOTE: The normal impedance between each terminal and the neutral is 9.35 m.ohms plus or minus 1.25 m.ohms at 25°C.
(a) If the impedance is in the specified limits: - make sure that the pins T/1, T/2, T/3 are electrically insulated from the case
- then, after you have removed the neutral lead, do a check of the pins T/1, T/2 or T/3 for short to ground.
- replace the GCU-APU [1XS] AMM 24-23-34-000-001 and AMM 24-23-34-400-001.
NOTE: Do not remove the APU GCU before you do the other steps of the trouble shooting.
2 If not insulated: - replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
B. Make sure that the aircraft electrical circuits operate correctly in APU configuration.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.