Feeder Short Circuits between the APU Generator and APU GLC
TASK 24-20-00-810-839-A
Feeder Short Circuits between the APU Generator and APU GLC
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-700-082-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-078-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:13 UTC
Feeder Short Circuits between the APU Generator and APU GLC
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242301 | |
| AMM 24-23-34-000-001 | Removal of the GCU-APU |
| AMM 24-23-34-400-001 | Installation of the GCU-APU |
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
Subtask 24-20-00-700-082-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
4. Fault IsolationNot applicable.
NOTE: As the APU GEN was set to OFF because of a true failure, the fault confirmation is not necessary.
Subtask 24-20-00-810-078-B ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message CHECK GEN APU FEEDER PIN T1 T2 T3 SHORT TO GROUND and the upper ECAM DU warning APU GEN FAULT:
Subtask 24-20-00-810-078-C ** ON A/C NOT FOR ALL - disconnect the feeders from the APU generator terminals T/1, T/2, T/3 and N.
- remove the wire connected on the GLC APU contactor pin A/D to the circuit breaker APU GEN EGIU2 (23XS).
- do a check of the wiring for short to ground on the feeders between the APU generator terminals T/1, T/2, T/3 and the APU GLC terminals A/F, A/E, A/D ASM 242301.
- repair the above feeder.
- replace the GCU-APU [1XS] AMM 24-23-34-000-001 and AMM 24-23-34-400-001.
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
A. If the fault symptom is identified by the CFDS message CHECK GEN APU FEEDER PIN T1 T2 T3 SHORT TO GROUND and the upper ECAM DU warning APU GEN FAULT:
Subtask 24-20-00-700-083-A ** ON A/C NOT FOR ALL - disconnect the feeders from the APU generator terminals T/1, T/2, T/3 and N.
- remove the wire connected to the APU/EXP power contactor module (29XN) pin 9 to the circuit breaker APU GEN EGIU2 (23XS).
- do a check of the wiring for short to ground on the feeders between the APU generator terminals T/1, T/2, T/3 and the APU/EXP power contactor module (29XN) pins 7, 8, 9 ASM 242301.
- repair the above feeder.
- replace the GCU-APU [1XS] AMM 24-23-34-000-001 and AMM 24-23-34-400-001.
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
B. Make sure that the aircraft electrical circuit operate correctly in APU configuration.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.