APU Generator Phase Inversion
TASK 24-20-00-810-837-A
APU Generator Phase Inversion
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-700-078-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-076-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:13 UTC
APU Generator Phase Inversion
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242301 | |
| AMM 24-23-34-000-001 | Removal of the GCU-APU |
| AMM 24-23-34-400-001 | Installation of the GCU-APU |
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
Subtask 24-20-00-700-078-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
4. Fault IsolationNot applicable.
NOTE: As the APU GEN was set to OFF because of a true failure, the fault confirmation is not necessary.
Subtask 24-20-00-810-076-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message CHECK GEN APU PHASE SEQ and the upper ECAM DU warning APU GEN FAULT:
Subtask 24-20-00-810-076-B ** ON A/C NOT FOR ALL - do a check of the wiring for phase inversion between respectively the APU generator pins T/1, T/2 and T/3 and the APU GLC pins A/F, A/E, A/D ASM 242301.
- repair it.
- do a check of the wiring for phase inversion between respectively the APU GCU pins B/1A, B/2B, B/3A and the APU GLC pins A/F, A/E and A/D ASM 242301.
- repair it.
- replace the GCU-APU [1XS] AMM 24-23-34-000-001 and AMM 24-23-34-400-001.
NOTE: Do not remove the APU GCU before you do the other steps of the trouble shooting.
(3) If the fault continues: - replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
A. If the fault symptom is identified by the CFDS message CHECK GEN APU PHASE SEQ and the upper ECAM DU warning APU GEN FAULT:
Subtask 24-20-00-700-079-A ** ON A/C NOT FOR ALL - do a check of the wiring for phase inversion between respectively the APU generator pins T/1, T/2 and T/3 and the APU/EXT power contactor module (29XN) pins 7, 8, 9 ASM 242301.
- repair it.
- do a check of the wiring for phase inversion between respectively the APU GCU pins B/1A, B/2B, B/3A and the APU/EXT power contactor module (29XN) pins 7, 8, 9 ASM 242301.
- repair it.
- replace the GCU-APU [1XS] AMM 24-23-34-000-001 and AMM 24-23-34-400-001.
NOTE: Do not remove the APU GCU before you do the other steps of the trouble shooting.
(3) If the fault continues:- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
B. Make sure that the aircraft electrical circuits operate correctly.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002