Failure of the APU Generator Control Unit
TASK 24-20-00-810-835-A
Failure of the APU Generator Control Unit
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-700-074-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-074-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:13 UTC
Failure of the APU Generator Control Unit
1. Possible Causes
- GCU-APU [1XS]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-23-34-000-001 | Removal of the GCU-APU |
| AMM 24-23-34-400-001 | Installation of the GCU-APU |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
Subtask 24-20-00-700-074-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
4. Fault IsolationNot applicable.
NOTE: As the APU GEN was set to OFF because of a true failure, the fault confirmation is not necessary.
Subtask 24-20-00-810-074-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message GCU APU and the upper ECAM DU warning APU GEN FAULT:
Subtask 24-20-00-700-075-A ** ON A/C NOT FOR ALL - replace the GCU-APU [1XS] AMM 24-23-34-000-001 and AMM 24-23-34-400-001.
B. Make sure that the aircraft electrical circuits operate correctly in APU configuration.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.