Failure of the IDG 1
TASK 24-20-00-810-822-A
Failure of the IDG 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-700-066-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-860-083-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:12 UTC
Failure of the IDG 1
1. Possible Causes
- Generator 1 contactor-module 30XN1
- Terminal block 1999VT
- Terminal block 400VT1
Terminal blocks T1, T2, T3 and N of IDG 1 - Receptacle 400VC1
[4000XU1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-21-51-000-040 | Removal of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-400-040 | Installation of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-41-00-740-004 | Operational Check of the GPCU via the CFDS |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 71-00-00-710-003 | Engine Automatic Start |
| AMM 71-00-00-710-028 | Engine Shutdown |
Subtask 24-20-00-700-066-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
4. Fault IsolationNot applicable.
NOTE: As the GEN 1 was set to OFF because of a true failure, the fault confirmation is not necessary.
CAUTION:
BEFORE YOU START THE CHECK OF IDG WIRING THAT INCLUDES CONNECTORS, EXAMINE EACH CONNECTOR TO MAKE SURE THAT THERE IS NO CONTAMINATION IN IT.
IF YOU FIND CONTAMINATION, CLEAN THE CONNECTOR AND CONNECT IT AGAIN.
IF THE FAILURE CONTINUES, DO THE TROUBLE SHOOTING PROCEDURE AS GIVEN BELOW.
Subtask 24-20-00-810-066-B ** ON A/C NOT FOR ALL A. If the fault symptom is identified by the CFDS message IDG 1 (GEN DIODE) and the upper ECAM DU warning GEN 1 FAULT:
(1) Do a visual inspection and repair or replace as necessary:
[4000XU1] AMM 24-21-51-000-040 and AMM 24-21-51-400-040.
Subtask 24-20-00-860-082-A ** ON A/C NOT FOR ALL (1) Do a visual inspection and repair or replace as necessary:
- Generator 1 contactor-module 30XN1
- Terminal block 1999VT
- Terminal block 400VT1
Terminal blocks T1, T2, T3 and N of IDG 1 - Receptacle 400VC1 .
B. Do this operational test to make sure that the system operates correctly.
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(2) On the ELEC panel 35VU:
(4) Start the engine 1 AMM 71-00-00-710-003.
Subtask 24-20-00-710-066-A ** ON A/C NOT FOR ALL (1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(2) On the ELEC panel 35VU:
- push, release and push again the GEN 1 pushbutton switch (3XU1).
(4) Start the engine 1 AMM 71-00-00-710-003.
C. Do this test:
5. Close-up| ACTION | RESULT |
|---|---|
On the ECAM control panel:
| On the lower ECAM display unit:
|
Subtask 24-20-00-860-083-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Stop the engine 1 AMM 71-00-00-710-028.
(2) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(3) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) Stop the engine 1 AMM 71-00-00-710-028.
(2) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(3) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.