Loss of the Generator 1 (Pins D, E, F, R, P, N of BTC1 shorted to ground)
TASK 24-20-00-810-806-A
Loss of the Generator 1 (Pins D, E, F, R, P, N of BTC1 shorted to ground)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-20-00-700-102-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-810-091-A ** ON A/C NOT FOR ALL
Subtask 24-20-00-860-106-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:10 UTC
Loss of the Generator 1 (Pins D, E, F, R, P, N of BTC1 shorted to ground)
1. Possible Causes
- feeder
- IDG1 feeders
- IDG [4000XU]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-21-51-000-040 | Removal of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-400-040 | Installation of the Integrated Drive Generator - IDG 1(2) |
| ASM 242202 | |
| AMM 24-41-00-740-004 | Operational Check of the GPCU via the CFDS |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 71-00-00-710-003 | Engine Automatic Start |
| AMM 71-00-00-710-028 | Engine Shutdown |
Subtask 24-20-00-700-102-A ** ON A/C NOT FOR ALL
A. Test
(1) Read the Class 1 Faults of the GCU or GPCU from the CFDS.
4. Fault Isolation(1) Read the Class 1 Faults of the GCU or GPCU from the CFDS.
NOTE: As the GEN1 was set to OFF because of a true failure, the test confirmation is not necessary.
Subtask 24-20-00-810-091-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the maintenance message CHECK BTC1 PIN D, E, F, R, P, N SHORT TO GROUND and by the warning GEN1 FAULT on the upper ECAM display unit:
Subtask 24-20-00-810-091-B ** ON A/C NOT FOR ALL - do a check of the feeder for short to ground between respectively:
. the pins A/G, A/H, A/J of the GLC1 and the main bus
. the pins A/M, A/L, A/K of the GLC1 and the pins A/D, A/E, A/F of the BTC1
. the pins A/R, A/P, A/N of the BTC1 and the pins A/N, A/P, A/R of the APU GLC ASM 242202
- repair it.
- do a check of the IDG1 feeders for intermittent short to ground between respectively the pins A/T1, B/T2, C/T3 of the IDG1 and the pins A/D, A/E, A/F of the GLC1.
- repair it.
- Replace the engine IDG [4000XU] AMM 24-21-51-000-040 and AMM 24-21-51-400-040.
- do a check and repair the wiring between respectively the pins A1, A6, A7, A8 of the IDG1 and the pins B/13D, B/13A, B/13B, B/13C of the GCU1.
A. If the fault symptom is identified by the maintenance message CHECK BTC1 PIN D, E, F, R, P, N SHORT TO GROUND and by the warning GEN1 FAULT on the upper ECAM display unit:
Subtask 24-20-00-710-078-A ** ON A/C NOT FOR ALL - do a check of the feeder for short to ground between respectively:
. the pins 4, 5, 6 of the generator 1 contactor module (30XN1) and the main bus
. the pins 10, 11, 12 of the generator 1 contactor module (30XN1) and the pins 10, 11, 12 of the APU/EXT power contactor module (29XN) ASM 242202.
- repair it.
- do a check of the IDG1 feeders for intermittent short to ground between respectively the pins A/T1, B/T2, C/T3 of the IDG1 and the pins 1, 2, 3 of the generator 1 contactor module (30XN1).
- repair it.
- Replace the engine IDG [4000XU] AMM 24-21-51-000-040 and AMM 24-21-51-400-040.
- do a check and repair the wiring between respectively the pins A1, A6, A7, A8 of the IDG1 and the pins B/13D, B/13A, B/13B, B/13C of the GCU1.
B. Do this operational test to make sure that the system operates correctly.
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(2) On the panel 35VU:
(4) Start the engine 1 AMM 71-00-00-710-003.
(5) Do this test:
5. Close-up(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(2) On the panel 35VU:
- push, release and push again the GEN1 pushbutton switch (3XU1).
(4) Start the engine 1 AMM 71-00-00-710-003.
(5) Do this test:
| ACTION | RESULT |
|---|---|
On the ECAM control panel:
| On the lower ECAM display unit:
|
Subtask 24-20-00-860-106-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Stop the engine 1 AMM 71-00-00-710-028.
(2) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(3) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) Stop the engine 1 AMM 71-00-00-710-028.
(2) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(3) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.