W DOC AIRBUS | TSM A320F

Low Oil Level of the IDG1


TASK 24-00-00-810-828-A
Low Oil Level of the IDG1


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 12-13-24-612-803
IDG Servicing - Filling of the IDG with Oil or Addition of Oil after a Level Check
AMM 24-21-00-210-805
Check of the Oil Level and Oil-Filter Differential-Pressure Indicator (DPI)
AMM 24-21-00-210-806
Visual Inspection of the IDG for Oil Leaks and Check of the Electrical Circuits
ASM 242101
AMM 24-21-51-000-803
Removal of the Integrated Drive Generator - IDG 1(2)
AMM 24-21-51-400-803
Installation of the Integrated Drive Generator - IDG 1(2)
AMM 24-22-34-000-001
Removal of the GCU-1(2)
AMM 24-22-34-400-001
Installation of the GCU-1(2)
AMM 24-41-00-740-002
Operational Check of the GAPCU via the CFDS
3. Fault Confirmation
Subtask 24-00-00-740-074-A ** ON A/C NOT FOR ALL
A. Test
   (1) On the overhead panel, on the ELEC control panel 35VU, push, release and push again the GEN1 pushbutton switch (3XU1).
   (2) After ten minutes, do the BITE test of the EPGS AMM 24-41-00-740-002.
4. Fault Isolation
Subtask 24-00-00-810-103-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message LOW OIL LEVEL/IDG1 (E1-4000XU):
Do a check of the IDG1 oil level at the sightglass AMM 24-21-00-210-805.
   (1) If the oil level is low:
  • Do a visual inspection of the IDG1 and the external system for oil leaks AMM 24-21-00-210-806.
  • Tubings
  • HEAT EXCHANGER-OIL/OIL,IDG [5002XM]
  • OIL COOLER-IDG, ENG [5001XM]
     (a) If you find leaks:
       1 Repair or replace the components as necessary to remove the leaks.
       2 On the overhead panel, on the ELEC control panel 35VU, push and release the GEN 1 pushbutton switch (3XU1) to do a reset of the protection functions of the GCU1.
       3 Wait six minutes.
       4 Do the BITE test of the EPGS AMM 24-41-00-740-002 again to make sure that the message is not shown.
       5 After six minutes, if the BITE test gives the maintenance message LOW OIL LEVEL/IDG1 (E1-4000XU), continue the trouble shooting to the Para A.(3) of the Fault Isolation.
     (b) If you find no leaks:
       1 Add oil AMM 12-13-24-612-803.
       2 On the overhead panel, on the ELEC control panel 35VU, push and release the GEN 1 pushbutton switch (3XU1) to do a reset of the protection functions of the GCU1.
       3 Wait six minutes.
       4 Do the BITE test of the EPGS AMM 24-41-00-740-002 again to make sure that the maintenance message is not shown.
       5 After six minutes, if the BITE test gives the maintenance message LOW OIL LEVEL/IDG1 (E1-4000XU), continue the trouble shooting in the Para. A.(3) of the Fault Isolation.
   (2) If the oil level is under the middle of the green band:
     (a) Add oil AMM 12-13-24-612-803.
       1 On the overhead panel, on the ELEC control panel 35VU, push and release the GEN 1 pushbutton switch (3XU1) to do a reset of the protection functions of the GCU1.
       2 Wait six minutes.
       3 Do the BITE test of the EPGS AMM 24-41-00-740-002 again to make sure that the maintenance message is not shown.
  • After six minutes, if the BITE test gives the maintenance message LOW OIL LEVEL/IDG1 (E1-4000XU), continue the trouble shooting in the Para. A.(3) of the Fault Isolation.
   (3) If the oil level is over the middle of the green band:
     (a) Do a check of the resistance of the Remote Oil Lever Sensor (ROLS) between pins B/3 and B/4 of the IDG1 (100 ohms plus or minus 50 ohms at 25 deg.C (77.00 deg.F)) ASM 242101
     (b) If the resistance value is out of the specified limits:
     (c) If the resistance value is in the specified limits:
  • Do a check of the wiring for an open circuit or a short to ground between pins A/13B, A/13A of the GCU1 and pins B/3, B/4 of the IDG1 ASM 242101.
       1 If the wiring is not correct:
  • Repair it.
       2 If the wiring is correct:
         a If the fault continues:
5. Close-up
Subtask 24-00-00-740-075-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:09 UTC