High-Delta Temperature Condition of the IDG 2 Oil Sensors


TASK 24-00-00-810-813-A
High-Delta Temperature Condition of the IDG 2 Oil Sensors


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 12-13-24-612-041
IDG Servicing - Filling of the IDG with Oil or Addition of Oil after a level Check
AMM 12-13-24-612-803
IDG Servicing - Filling of the IDG with Oil or Addition of Oil after a Level Check
AMM 24-21-00-210-044
Inspection of the Filter Element(s)
AMM 24-21-00-210-046
Check IDG Oil Level and Differential Pressure Indicator (DPI)
AMM 24-21-00-210-805
Check of the Oil Level and Oil-Filter Differential-Pressure Indicator (DPI)
AMM 24-21-00-210-807
Inspection of the IDG Oil Charge and Scavenge Filter Elements
AMM 24-21-00-710-803
Operational Test of the IDG Disconnect and Reconnect (Reset) Function - Engine Static
AMM 24-21-00-720-041
Operational Test of the IDG Disconnect and Reconnect (Reset) Function - Engine in Operation
AMM 24-21-00-920-040
Drain IDG Oil System, Discard Filter Element(s) and Replenish
AMM 24-21-00-920-802
Drain, Remove and Discard the Scavenge and Charge Filter Elements and Replenish IDG Oil System
ASM 242101
AMM 24-21-51-000-040
Removal of the Integrated Drive Generator - IDG 1(2)
AMM 24-21-51-000-803
Removal of the Integrated Drive Generator - IDG 1(2)
AMM 24-21-51-400-040
Installation of the Integrated Drive Generator - IDG 1(2)
AMM 24-21-51-400-803
Installation of the Integrated Drive Generator - IDG 1(2)
AMM 24-22-34-000-001
Removal of the GCU-1(2)
AMM 24-22-34-400-001
Installation of the GCU-1(2)
3. Fault Confirmation
Subtask 24-00-00-869-053-A ** ON A/C NOT FOR ALL
A. Test
   (1) Not applicable, you cannot confirm this fault on the ground.
4. Fault Isolation
CAUTION: BEFORE YOU START THE CHECK OF IDG WIRING THAT INCLUDES CONNECTORS, EXAMINE EACH CONNECTOR TO MAKE SURE THAT THERE IS NO CONTAMINATION IN IT. IF YOU FIND CONTAMINATION, CLEAN THE CONNECTOR AND CONNECT IT AGAIN. IF THE FAILURE CONTINUES, DO THE TROUBLE SHOOTING PROCEDURE AS GIVEN BELOW.
Subtask 24-00-00-810-066-D ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message IDG2 (E2-4000XU) OIL DELTA TEMP/ GCU2 (1XU2):
   (1) If the DPI is extended:
   (2) If the DPI is not extended:
     (a) If there is contamination of the IDG 2 charge and scavenge filters:
     (b) If there is no contamination of the IDG 2 charge and scavenge filters:
   (3) If the fault continues:
  • do a check of the resistance of the oil inlet and outlet temperature-sensors of the IDG 2 ASM 242101 between:
    . pin B/7 and pin B/8 (100 ohms plus or minus 10 ohms at the ambient temperature of the IDG case)
    . pin B/8 and pin B/9 (100 ohms plus or minus 10 ohms at the ambient temperature of the IDG case).
     (a) If the resistance values are out of the specified limits:
     (b) If the resistance values are in the specified limits:
  • do a check of the wiring of the oil inlet and outlet temperature-sensors ASM 242101 for an open circuit, a short to ground or a short to shield condition between:
    . pin B/7 of the IDG 2 and pin A/9C of the GCU 2
    . pin B/8 of the IDG 2 and pin A/9D of the GCU 2
    . pin B/9 of the IDG 2 and pin A/10C of the GCU 2
    . pins A/9C and A/10D of the GCU 2 (do a check for a short to shield)
    . pins A/9D and A/10D of the GCU 2 (do a check for a short to shield)
    . pins A/10C and A/10D of the GCU 2 (do a check for a short to shield).
       1 If the wiring is not correct:
  • repair or replace as necessary.
       2 If the wiring is correct:
       3 If the fault continues:
Subtask 24-00-00-810-066-G ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message IDG2 (E2-4000XU) OIL TEMP/ GCU2 (1XU2):
   (1) If the DPI is extended:
   (2) If the DPI is not extended:
     (a) If there is contamination of the IDG 2 charge and scavenge filters:
     (b) If there is no contamination of the IDG 2 charge and scavenge filters:
   (3) If the fault continues:
  • Do an electrical resistance test of the inlet and outlet oil temperature-sensors of the IDG 2 ASM 242101 between:
    . Pin B/7 and pin B/8 (100 ohms plus or minus 10 ohms at the ambient temperature of the IDG case)
    . Pin B/8 and pin B/9 (100 ohms plus or minus 10 ohms at the ambient temperature of the IDG case).
     (a) If the resistance values are out of the specified limits:
     (b) If the resistance values are in the specified limits:
  • Do a check of the wiring of the inlet and outlet oil temperature-sensors ASM 242101 for an open circuit, for a short to ground or a short to shield condition between:
    . Pin B/7 of the IDG 2 and pin A/9C of the GCU 2
    . Pin B/8 of the IDG 2 and pin A/9D of the GCU 2
    . Pin B/9 of the IDG 2 and pin A/10C of the GCU 2
    . Pins A/9C and A/10D of the GCU 2 (do a check for a short to shield)
    . Pins A/9D and A/10D of the GCU 2 (do a check for a short to shield)
    . Pins A/10C and A/10D of the GCU 2 (do a check for a short to shield).
       1 If the wiring is not correct:
  • Repair or replace as necessary.
       2 If the wiring is correct:
       3 If the fault continues:
Subtask 24-00-00-860-053-A ** ON A/C NOT FOR ALL
B. After the subsequent flight, make sure that the fault does not continue.