Failure of the IDG 2 Oil-Out Temperature Bulb or its Wiring
TASK 24-00-00-810-809-A
Failure of the IDG 2 Oil-Out Temperature Bulb or its Wiring
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-00-00-740-062-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 24-00-00-810-064-D ** ON A/C NOT FOR ALL
Subtask 24-00-00-810-064-G ** ON A/C NOT FOR ALL
Subtask 24-00-00-740-063-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:39:02 UTC
Failure of the IDG 2 Oil-Out Temperature Bulb or its Wiring
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-21-00-612-043 | Servicing of the IDG after Oil Chemical Contamination |
| AMM 24-21-00-612-804 | Servicing of the IDG after Oil Chemical Contamination |
| ASM 242101 | |
| AMM 24-21-51-000-040 | Removal of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-000-803 | Removal of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-400-040 | Installation of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-400-803 | Installation of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-22-34-000-001 | Removal of the GCU-1(2) |
| AMM 24-22-34-400-001 | Installation of the GCU-1(2) |
| AMM 24-41-00-740-002 | Operational Check of the GAPCU via the CFDS |
Subtask 24-00-00-740-062-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 24-00-00-810-064-D ** ON A/C NOT FOR ALL
CAUTION:
AFTER AN IDG OIL LOW PRESSURE (LO PR) OR OVERHEAT (OVHT) CONDITION:
A. If the BITE test gives the maintenance message IDG2 (E2-4000XU) OIL OUT TEMP SENSE/ GCU2 (1XU2) and the upper ECAM-DU warnings IDG 2 OIL OVHT and GEN 2 FAULT: - DO NOT CONNECT THE DISCONNECTED IDG1(2) AGAIN, AND
- REPLACE IDG1(2).
- Replace IDG-ENG 2 [4000XU2] AMM 24-21-51-000-803 and AMM 24-21-51-400-803
- Do the servicing of the IDG 2 external oil-circuit with new oil after oil chemical contamination AMM 24-21-00-612-804.
- Do a check of the wiring of the oil outlet temperature-sensor ASM 242101 for a high resistance or an open circuit between:
. Pin B/7 of the IDG 2 and pin A/9C of the GCU 2
. Pin B/8 of the IDG 2 and pin A/9D of the GCU 2.
- Repair or replace as necessary.
- Replace GCU-2 [1XU2] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
CAUTION:
AFTER AN IDG OIL LOW PRESSURE (LO PR) OR OVERHEAT (OVHT) CONDITION:
A. If the BITE test gives the maintenance message IDG2 (E2-4000XU) OIL OUT TEMP SENSE/ GCU2 (1XU2) and the upper ECAM-DU warnings IDG 2 OIL OVHT and GEN 2 FAULT: - DO NOT CONNECT THE DISCONNECTED IDG1(2) AGAIN, AND
- REPLACE IDG1(2).
- Replace the engine 2 IDG [4000XU] AMM 24-21-51-000-040 and AMM 24-21-51-400-040
- Do the servicing of the IDG 2 external oil-circuit with new oil after oil chemical contamination AMM 24-21-00-612-043.
- Do a check of the wiring of the oil outlet temperature-sensor ASM 242101 for a high resistance or an open circuit between:
. Pin B/7 of the IDG 2 and pin A/9C of the GCU 2
. Pin B/8 of the IDG 2 and pin A/9D of the GCU 2.
- Repair or replace as necessary.
- Replace the GCU-2 [1XU2] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
B. Do the test given in Para. 3.