W DOC AIRBUS | TSM A320F

Failure of the Generator Control Unit 2


TASK 24-00-00-810-805-A
Failure of the Generator Control Unit 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-22-34-000-001
Removal of the GCU-1(2)
AMM 24-22-34-400-001
Installation of the GCU-1(2)
AMM 24-41-00-740-002
Operational Check of the GAPCU via the CFDS
3. Fault Confirmation
Subtask 24-00-00-740-052-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the GAPCU AMM 24-41-00-740-002.
     (a) If the BITE test gives the message TEST FAILED:
  • do the trouble shooting given in Para 4.A.
     (b) If the BITE test gives the message TEST PASSED:
  • stop the trouble shooting.
4. Fault Isolation
Subtask 24-00-00-810-056-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the message TEST FAILED:
  • push the line key adjacent to the TEST FAILED message.
   (1) If the maintenance message GCU2 (1XU2) comes into view:
Subtask 24-00-00-740-053-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.