Power Supply Interruption
TASK 24-00-00-810-802-A
Power Supply Interruption
1. Possible Causes
2. Fault Confirmation
Subtask 24-00-00-710-051-A
Subtask 24-00-00-810-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:38:52 UTC
Power Supply Interruption
1. Possible Causes
2. Fault Confirmation
Subtask 24-00-00-710-051-A
A. Not applicable: this message is intermittent.
3. Fault IsolationSubtask 24-00-00-810-051-A
A. If the POST FLIGHT REPORT gives the maintenance message POWER SUPPLY INTERRUPT:
Subtask 24-00-00-810-052-A - No maintenance action is required necessary.
NOTE: A computer gives a POWER SUPPLY INTERRUPT message if the electrical power stops for more than 200ms and then starts again.
B. If the system that gives the message POWER SUPPLY INTERRUPT has been also faulty for other system(s), since the start of the flight, do the BITE test of this system.
Subtask 24-00-00-810-053-A - If the system test is OK, no maintenance action is necessary.
C. If there is (are) additional message(s) related to the Aircraft Electrical Power System:
- Do the related trouble shooting procedure.