NO TEMPERATURE SELECT AVAILABLE on Flight Attendant Panel (FAP)
TASK 23-73-71-810-802-A
NO TEMPERATURE SELECT AVAILABLE on Flight Attendant Panel (FAP)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-71-710-051-A ** ON A/C NOT FOR ALL
Subtask 23-73-71-810-053-A ** ON A/C NOT FOR ALL
Subtask 23-73-71-860-050-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:05 UTC
NO TEMPERATURE SELECT AVAILABLE on Flight Attendant Panel (FAP)
1. Possible Causes
- DIR-CIDS, 1 [101RH]
- DIR-CIDS, 2 [102RH]
- CONT-AIR COND SYSTEM 1 [47HH]
- CONT-AIR COND SYSTEM 2 [57HH]
- SDAC-1 [1WV1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 23-73-71-710-051-A ** ON A/C NOT FOR ALL
A. In the cabin, on the FAP:
4. Fault Isolation- Go to the Cabin Temperature page.
- If you see a blue card with the message "NO TEMPERATURE SELECT AVAILAVBLE", go to the Para. Fault Isolation.
Subtask 23-73-71-810-053-A ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
Subtask 23-73-71-810-054-A ** ON A/C NOT FOR ALL - Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
- Do the related fault isolation procedure.
- Do the test given in Para. 3.
- Do the test given in Para. 3.
B. If the fault continues:
(1) Replace the DIR-CIDS, 1 [101RH] with DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
(2) Do the test given in Para. 3.
(a) If the fault does not continue:
Subtask 23-73-71-810-055-A ** ON A/C NOT FOR ALL (1) Replace the DIR-CIDS, 1 [101RH] with DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
(2) Do the test given in Para. 3.
(a) If the fault does not continue:
- Replace the initial DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- Do the test given in Para. 3.
- Continue the trouble shooting procedure.
C. If the fault continues:
(1) Replace the CONT-AIR COND SYSTEM 1 [47HH] with CONT-AIR COND SYSTEM 2 [57HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
(2) Do the test given in Para. 3.
(a) If the fault does not continue:
Subtask 23-73-71-810-056-A ** ON A/C NOT FOR ALL (1) Replace the CONT-AIR COND SYSTEM 1 [47HH] with CONT-AIR COND SYSTEM 2 [57HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
(2) Do the test given in Para. 3.
(a) If the fault does not continue:
- Replace the initial CONT-AIR COND SYSTEM 1 [47HH] AMM 21-61-34-400-002.
- Do the test given in Para. 3.
- Continue the trouble shooting procedure.
D. If the fault continues:
(1) Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(2) Do the test given in Para. 3.
5. Close-up(1) Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(2) Do the test given in Para. 3.
Subtask 23-73-71-860-050-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
(1) Make sure that the work area is clean and clear of tools and other items.
(1) Make sure that the work area is clean and clear of tools and other items.