W DOC AIRBUS | TSM A320F

NO TEMPERATURE SELECT AVAILABLE on Flight Attendant Panel (FAP)


TASK 23-73-71-810-802-A
NO TEMPERATURE SELECT AVAILABLE on Flight Attendant Panel (FAP)


1. Possible Causes
  • DIR-CIDS, 1 [101RH]
  • DIR-CIDS, 2 [102RH]
  • CONT-AIR COND SYSTEM 1 [47HH]
  • CONT-AIR COND SYSTEM 2 [57HH]
  • SDAC-1 [1WV1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 23-73-71-710-051-A ** ON A/C NOT FOR ALL
A. In the cabin, on the FAP:
  • Go to the Cabin Temperature page.
  • If you see a blue card with the message "NO TEMPERATURE SELECT AVAILAVBLE", go to the Para. Fault Isolation.
4. Fault Isolation
Subtask 23-73-71-810-053-A ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
   (1) If the test(s) give(s) a fault message related to the FAP or the DIR-CIDS 1 or DIR-CIDS 2:
  • Do the related fault isolation procedure.
  • Do the test given in Para. 3.
   (2) If the test(s) does not give a fault message:
  • Do the test given in Para. 3.
Subtask 23-73-71-810-054-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) Replace the DIR-CIDS, 1 [101RH] with DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
   (2) Do the test given in Para. 3.
     (a) If the fault does not continue:
     (b) If the fault continues:
  • Continue the trouble shooting procedure.
Subtask 23-73-71-810-055-A ** ON A/C NOT FOR ALL
C. If the fault continues:
   (1) Replace the CONT-AIR COND SYSTEM 1 [47HH] with CONT-AIR COND SYSTEM 2 [57HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
   (2) Do the test given in Para. 3.
     (a) If the fault does not continue:
     (b) If the fault continues:
  • Continue the trouble shooting procedure.
Subtask 23-73-71-810-056-A ** ON A/C NOT FOR ALL
D. If the fault continues:
   (1) Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
   (2) Do the test given in Para. 3.
5. Close-up
Subtask 23-73-71-860-050-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
   (1) Make sure that the work area is clean and clear of tools and other items.
[Rev.8 from Aug 2018] 2026.04.04 04:26:05 UTC