W DOC AIRBUS | TSM A320F

FAP screen blank/white


TASK 23-73-00-810-982-A
FAP screen blank/white


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 205221
ESPM 205222
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-12-000-007
Removal of the Flight Attendant Panel
AMM 23-73-12-400-007
Installation of the Flight Attendant Panel
ASM 237323
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-73-00-710-407-A ** ON A/C NOT FOR ALL
A. Do the CIDS Interface and Power-Up test through the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 23-73-00-810-799-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-800-A ** ON A/C NOT FOR ALL
B. If there is confirmation of the fault:
   (1) Do a check if the FAP Power-up page shows before the blank/white screen:
     (a) If the FAP Power-up page shows:
       1 Do the test given in Para. 3.
     (b) If the FAP Power-up page does not show:
       1 Disconnect the connector A from the FAP [120RH] .
       2 Do a check and repair the wiring from:
  • FAP (120RH) connector A/18 and CB 170RH
  • FAP (120RH) connector A/19 and CB 171RH
  • FAP (120RH) connector A/20 and GND
  • FAP (120RH) connector A/21 and GND
    ASM 237323.
       3 Connect the connector A to the FAP [120RH] .
       4 Do the test given in Para. 3.
   (2) If the fault continues:
     (a) Disconnect the connector A from the FAP [120RH] .
     (b) Remove the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
     (c) Do a check for continuity ESPM 205221, short circuit ESPM 205222 and correctly installed pins of the wirings from:
  • DIR-CIDS, 1 (101RH) connector AB/14A and FAP (120RH) connector A/50
  • DIR-CIDS, 2 (102RH) connector AB/14A and FAP (120RH) connector A/50
    ASM 237323.
     (d) Install the DIR-CIDS, 2 [102RH] and DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
     (e) Connect the connector A to the FAP [120RH] .
     (f) Do the test given in Para. 3.
   (3) If the fault continues:
     (a) Replace the FAP [120RH] AMM 23-73-12-000-007 and AMM 23-73-12-400-007.
     (b) Do the test given in Para. 3.