Inoperative Forward Attendant Panel (FAP)
TASK 23-73-00-810-979-A
Inoperative Forward Attendant Panel (FAP)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-405-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-791-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:05 UTC
Inoperative Forward Attendant Panel (FAP)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-12-000-002 | Removal of the Forward Attendant Panel |
| AMM 23-73-12-400-002 | Installation of the Forward Attendant Panel |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-405-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the BITE-test of the Cabin Intercommunication Data System (CIDS) through the CFDS AMM 23-73-00-740-005.
4. Fault Isolation(1) Do the BITE-test of the Cabin Intercommunication Data System (CIDS) through the CFDS AMM 23-73-00-740-005.
Subtask 23-73-00-810-791-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-792-A ** ON A/C NOT FOR ALL B. If the test confirms the fault:
(1) Do a reset of the FAP as follows:
(a) Open this CB:
on 121VU: 170RH COM NAV/CIDS/FLT ATTND PNL1
(b) Wait at least 10 seconds and then close this CB:
on 121VU: 170RH COM NAV/CIDS/FLT ATTND PNL1
(c) Wait at least 10 seconds.
(d) Do the test given in Para. 3.
(2) If the fault continues:
(a) Replace the FAP [120RH] AMM 23-73-12-000-002 and AMM 23-73-12-400-002.
(b) Do the test given in Para. 3.
(3) If the fault continues:
(a) Replace the active DIR-CIDS, 1 [101RH] or DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
(b) Do the test given in Para. 3.
(1) Do a reset of the FAP as follows:
(a) Open this CB:
on 121VU: 170RH COM NAV/CIDS/FLT ATTND PNL1
(b) Wait at least 10 seconds and then close this CB:
on 121VU: 170RH COM NAV/CIDS/FLT ATTND PNL1
(c) Wait at least 10 seconds.
(d) Do the test given in Para. 3.
(2) If the fault continues:
(a) Replace the FAP [120RH] AMM 23-73-12-000-002 and AMM 23-73-12-400-002.
(b) Do the test given in Para. 3.
(3) If the fault continues:
(a) Replace the active DIR-CIDS, 1 [101RH] or DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
(b) Do the test given in Para. 3.