CIDS - director malfunction(s)
TASK 23-73-00-810-978-A
CIDS - director malfunction(s)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-403-A
Subtask 23-73-00-810-790-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:05 UTC
CIDS - director malfunction(s)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-403-A
A. Test
Not applicable, the fault is evident.
4. Fault IsolationNot applicable, the fault is evident.
Subtask 23-73-00-810-790-A
A. Replace the CIDS Directors
NOTE: Refer to the VSB Z010H-23-039 for a permanent solution.
NOTE: If the part numbers of the new and the old directors are the same, the fault can occur again after some time.
(1) Replace the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] , refer to AMM 23-73-34-000-001 and AMM 23-73-34-400-001.