CIDS - Fault in CIDS MID BUS L / Director 2
TASK 23-73-00-810-976-A
CIDS - Fault in CIDS MID BUS L / Director 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-399-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-778-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:04 UTC
CIDS - Fault in CIDS MID BUS L / Director 2
1. Possible Causes
- DIR-CIDS, 1 [101RH]
- DIR-CIDS, 2 [102RH]
- DEU-B [300RH5]
- DEU-B [300RH1]
- DEU mount 2015VU1
- DEU mount 2011VU3
- wiring
- DEU mount 2011VU1
- DECODER/ENCODER UNIT B [300RH7]
- DEU TERMINATION BOX [309RH1]
- DEU CONNECTION BOX [308RH5]
- DEU CONNECTION BOX [308RH1]
- DEU CONNECTION BOX [308RH3]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237306 | |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AMM 23-73-42-000-001 | Removal of the Connection Box (208RH,308RH) |
| AMM 23-73-42-400-001 | Installation of the Connection Box (208RH,308RH) |
| AMM 23-73-43-000-001 | Removal of the Termination Box (209RH,309RH) |
| AMM 23-73-43-400-001 | Installation of the Termination Box (209RH,309RH) |
| AMM 23-73-47-000-001 | Removal of the Decoder/Encoder Unit B (300RH) |
| AMM 23-73-47-400-001 | Installation of the Decoder/Encoder Unit B (300RH) |
| AMM 23-73-48-000-001 | Removal of the DEU A/DEU B - Mount |
| AMM 23-73-48-400-001 | Installation of the DEU A/DEU B - Mount |
Subtask 23-73-00-710-399-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS1/CIDS BUS test through the CFDS/MCDU.
(2) Do the CIDS1/DEU-B test through the CFDS/MCDU.
Subtask 23-73-00-710-399-B ** ON A/C NOT FOR ALL 4. Fault Isolation(1) Do the CIDS1/CIDS BUS test through the CFDS/MCDU.
(2) Do the CIDS1/DEU-B test through the CFDS/MCDU.
Subtask 23-73-00-810-778-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-779-F ** ON A/C NOT FOR ALL B. If the CIDS2/CIDS BUS test gives the maintenance message CIDS MID BUS L:
Subtask 23-73-00-810-779-J ** ON A/C NOT FOR ALL - Make sure that at least one cabin door is open.
- In the cockpit, on the overhead panel 25VU:
Make sure that the EMER EXIT LT switch (4WL) is in the OFF position. - Remove the DIR-CIDS (101RH) AMM 23-73-34-000-001.
- Close these CBs:
49VU: 157RH (G02) CIDS/DIR 2/ESS,
121VU:156RH (M07) CIDS/DIR 2/NORM. - Wait for approx. 120 s.
- Do the CIDS2/CIDS BUS test through the CFDS/MCDU.
- Install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- Remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
- During the installation of the DIR-CIDS, 1 (101RH) do not close these CBs:
49VU: 157RH (G02) CIDS/DIR 2/ESS,
121VU:156RH (M07) CIDS/DIR 2/NORM. - Install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- Do the CIDS1/CIDS BUS test through the CFDS/MCDU.
- Install a new DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- Remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001.
- Open these CBs:
49VU: 153RH COM/CIDS/DEU B/ESS,
121VU: 162RH COM NAV/CIDS/DEU B/NORM. - Make sure that the resistance (line to line) at DIR-CIDS (101RH) and (102RH) connector AA/D14 and connector AA/E14 is between approx. 80 and 200 ohms ASM 237306.
- Make sure that the resistance (line to GND) is not less than 50 ohms (short circuit) between:
DIR-CIDS (101RH) and (102RH) connector AA/D14 and GND,
DIR-CIDS (101RH) and (102RH) connector AA/E14 and GND ASM 237306.
- Remove the DEU-B [300RH5] AMM 23-73-47-000-001.
- Install the DIR-CIDS (101RH) and DIR-CIDS (102RH) AMM 23-73-34-400-001.
- Close these CBs:
49VU: 153RH COM/CIDS/DEU B/ESS,
121VU: 162RH COM NAV/CIDS/DEU B/NORM. - Do the CIDS BITE test through the CFDS/MCDU AMM 23-73-00-740-005.
- Install a new DEU-B [300RH5] AMM 23-73-47-400-001.
- Install the removed DEU-B [300RH5] AMM 23-73-47-400-001.
- Do the steps 4. B. (5) (a) again for the subsequent DEU(s) until the maintenance message stops: ASM 237306.
DEU-B [300RH1]
- Remove the DEU-B [300RH5] AMM 23-73-47-000-001.
- Do a check for a short circuit again.
- Install a new DEU-B [300RH5] AMM 23-73-47-400-001.
- Disconnect the electrical connector 7247VC1 from the DEU mount 2015VU1 AMM 23-73-48-000-001.
- Do a check for a short circuit again.
- Install a new DEU mount 2015VU1 AMM 23-73-48-000-001 and AMM 23-73-48-400-001.
- Install the removed DEU-B [300RH5] AMM 23-73-47-400-001.
- Reconnect the electrical connector to the DEU mount 2015VU1 AMM 23-73-48-400-001.
- Disconnect the electrical connector 7201VC3 from the DEU mount 2011VU3 AMM 23-73-48-000-001.
- Do a check for a short circuit again.
- b.1. If there is no short circuit:
- Do a check for a short circuit at the disconnected connector 7201VC3 between pin 9 and GND (pin 11) and between pin 10 and GND (pin 11).
- b.1.1. If there is a short circuit:
- Repair the wiring between the DEU mount 2011VU3 and the DEU mount 2015VU1 ASM 237306.
- b.1.2. If there is no short circuit:
- Install a new DEU mount 2011VU3 AMM 23-73-48-400-001.
- b.2. If there is a short circuit:
- Reconnect the electrical connector to the DEU mount 2011VU3 AMM 23-73-48-400-001.
- Do the steps (4. B. (5) (b) 2 b) again for the subsequent DEU(s) and DEU mount(s) until the maintenance message stops: ASM 237306.
DEU-B [300RH1] and DEU mount 2011VU1
- Disconnect the electrical connector 7247VC1 from the DEU mount 2015VU1 AMM 23-73-48-000-001.
- Make sure that the resistance (line to line) is not more than 200 ohms (open circuit) between:
DEU mount 2015VU1 pin A/1 and pin A/2.
- Install a new DEU mount 2015VU1 AMM 23-73-48-400-001.
- Reconnect the electrical connector to the DEU mount 2015VU1 AMM 23-73-48-400-001.
- Disconnect the electrical connector 7201VC1 from the DEU mount 2011VU1 AMM 23-73-48-000-001.
- Do a check of the wiring (continuity-check) between:
DIR-CIDS (102RH) connector AA/D14 and the connector 7201VC1 pin A/1,
DIR-CIDS (102RH) connector AA/E14 and the connector 7201VC1 pin A/2.
- Repair the wiring between the DIR-CIDS (102RH) and the connector 7201VC1 ASM 237306.
- Do a check of the wiring (continuity-check) between:
DEU mount 2011VU1 pin A/1 and pin A/9,
DEU mount 2011VU1 pin A/2 and pin A/10.
- Install a new DEU mount 2011VU1 AMM 23-73-48-000-001 and AMM 23-73-48-400-001.
- Reconnect the connector 7201VC1 to the DEU mount 2011VU1 AMM 23-73-48-400-001.
- Do the steps 4. B. (6) again for the subsequent DEU mounts until the maintenance message stops:
DIR-CIDS (102RH) and DEU mount 2011VU3 /connector 7201VC3,
DIR-CIDS (102RH) and DEU mount 2015VU1 /connector 7247VC1.
- Remove the DEU-B [300RH5] AMM 23-73-47-000-001.
- Do a check for a short circuit again.
- Install a new DEU-B [300RH5] AMM 23-73-47-400-001.
- Install the removed DEU-B [300RH5] AMM 23-73-47-400-001.
- Diconnect the electrical connector 7247VC1 from the DEU mount 2015VU1 ASM 237306.
- Do a check for a short circuit again.
- Reconnect the electrical connector to the DEU mount 2015VU1 AMM 23-73-48-400-001.
- Do the steps 4. B. (7) again for the subsequent DEU(s) and DEU mount(s) until the maintenance message stops: ASM 237306.
DEU mount 2011VU3 ,
DEU-B [300RH1] and DEU mount 2011VU1 .
- Do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306.
- Repair the wiring between the related DEU mount 2011VUxx and the DEU mount 2015VUxx/2011VUxx ASM 237306.
- Install a new DEU mount 2015VU1 AMM 23-73-48-400-001.
B. If the CIDS2 Interface and Power-Up Test gives the maintenance message CIDS MID BUS L/ DIR2 (102RH):
Subtask 23-73-00-810-779-K ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open,
- remove the DIR-CIDS (101RH) AMM 23-73-34-000-001,
- close these CBs:
49VU: 157RH COM CIDS/DIR ESS/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS,
120VU: 156RH COM NAV/CIDS/DIR NORM/2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2, - wait for approx. 120 s,
- do the CIDS2 Interface and Power-Up Test via the CFDS/MCDU AMM 23-73-00-740-005.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- Do the test given in Para. 3.
- remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
- during the installation of the DIR-CIDS, 1 (101RH) do not close these CBs:
49VU: 157RH COM CIDS/DIR ESS/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS,
120VU: 156RH COM NAV/CIDS/DIR NORM/2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2, - install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- Do the test given in Para. 3.
- install a new DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- Do the test given in Para. 3.
- remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001
- open these CBs:
49VU: 153RH COM/CIDS/DEU B/ESS
121VU: 162RH COM NAV/CIDS/DEU B/NORM - make sure that the resistance (line to line) at DIR-CIDS (101RH) and (102RH) connector AA/D14 and connector AA/E14 is between approx. 80 and 140 ohms ASM 237306.
- make sure that the resistance (line to GND) is not less than 7 k ohms (short circuit) between:
DIR-CIDS (101RH) and (102RH) connector AA/D14 and GND,
DIR-CIDS (101RH) and (102RH) connector AA/E14 and GND. ASM 237306
- remove the DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-000-001
- install the DIR-CIDS (101RH) and DIR-CIDS (102RH) AMM 23-73-34-400-001.
- close these CBs:
49VU: 153RH COM/CIDS/DEU B/ESS
121VU: 162RH COM NAV/CIDS/DEU B/NORM - Do the test given in Para. 3.
- install a new DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- Do the test given in Para. 3.
- install the removed DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- do the steps 4. B. (5) (a) again for the subsequent DEU(s) until the maintenance message stops: ASM 237306
DEU-B [300RH1]
- remove the DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-000-001.
- do a check for a short circuit again.
- install a new DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- Do the test given in Para. 3.
- disconnect the electrical connector from the DEU TERMINATION BOX [309RH1] ASM 237306.
- do a check for a short circuit again.
- install a new DEU TERMINATION BOX [309RH1] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- Do the test given in Para. 3.
- install the removed DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001,
- reconnect the electrical connector to the DEU TERMINATION BOX [309RH1] ,
- disconnect the electrical connector from the DEU CONNECTION BOX [308RH5] ,
- do a check for a short circuit again.
- b.1. If there is no short circuit:
- do a check for a short circuit at the disconnected connector between pin 9 and GND (pin 4) and between pin 10 and GND (pin 4).
- b.1.1. If there is a short circuit:
- repair the wiring between the DEU CONNECTION BOX [308RH5] and the DEU TERMINATION BOX [309RH1] ASM 237306.
- Do the test given in Para. 3.
- b.1.2. If there is no short circuit:
- install a new DEU CONNECTION BOX [308RH5] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- Do the test given in Para. 3.
- b.2. If there is a short circuit:
- reconnect the electrical connector to the DEU CONNECTION BOX [308RH5] ,
- do the steps (4. B. (5) (b) 2 b) again for the subsequent DEU(s) and DEU CONNECTION BOX(es) until the maintenance message stops for:
DEU-B [300RH1] and DEU CONNECTION BOX [308RH1] .
- disconnect the electrical connector DEU TERMINATION BOX [309RH1] ASM 237306,
- make sure that the resistance (line to line) is not more than 140 ohms (open circuit) between:
DEU TERMINATION BOX [309RH1] pin A/1 and pin A/2
- install a new DEU TERMINATION BOX [309RH1] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- Do the test given in Para. 3.
- reconnect the electrical connector to the DEU TERMINATION BOX [309RH1] .
- disconnect the electrical connector from the DEU CONNECTION BOX [308RH1] ASM 237306.
- do a check of the wiring (continuity-check) between:
DIR-CIDS (102RH) connector AA/D14 and the DEU CONNECTION BOX [308RH1] connector pin A/2,
DIR-CIDS (102RH) connector AA/E14 and the DEU CONNECTION BOX [308RH1] connector pin A/1.
- repair the wiring between the DIR-CIDS (102RH) and the connector DEU CONNECTION BOX [308RH1] ASM 237306.
- Do the test given in Para. 3.
- do a check of the wiring (continuity-check) between:
DEU CONNECTION BOX [308RH1] pin A/1 and pin A/9 ,
DEU CONNECTION BOX [308RH1] pin A/2 and pin A/10.
- install a new DEU CONNECTION BOX [308RH1] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- Do the test given in Para. 3.
- reconnect the connector to the DEU CONNECTION BOX [308RH1] .
- do the steps 4. B. (6) again for the subsequent DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops:
DIR-CIDS (102RH) and DEU CONNECTION BOX [308RH5] ,
DIR-CIDS (102RH) and DEU TERMINATION BOX [309RH1] .
- remove the DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-000-001.
- do a check for a short circuit again.
- install a new DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- Do the test given in Para. 3.
- install the removed DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- diconnect the electrical connector from the DEU TERMINATION BOX [309RH1] ASM 237306,
- do a check for a short circuit again.
- reconnect the electrical connector to the DEU TERMINATION BOX [309RH1] ,
- do the steps 4. B. (7) again for the subsequent DEU(s) and DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops for: ASM 237306
DEU CONNECTION BOX [308RH5] ,
DEU-B [300RH1] and DEU CONNECTION BOX [308RH1] ,
- do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306
- repair the wiring between the related DEU CONNECTION BOX 308RHxx and the DEU CONNECTION/ TERMINATION BOX(es) 308RHxx/309RHxx ASM 237306.
- Do the test given in Para. 3.
- install a new DEU TERMINATION BOX [309RH1] AMM 23-73-48-400-001.
- Do the test given in Para. 3.
B. If the CIDS2 Interface and Power-Up Test gives the maintenance message CIDS MID BUS L/ DIR2 (102RH):
Subtask 23-73-00-810-779-O ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open,
- On the overhead-panel 25VU:
make sure that the EMER EXIT LT switch (4WL) is in the OFF position, - remove the DIR-CIDS (101RH) AMM 23-73-34-000-001,
- close these CBs:
49VU: 157RH COM CIDS/DIR ESS/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS,
120VU: 156RH COM NAV/CIDS/DIR NORM/2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2, - wait for approx. 120 s,
- do the CIDS2 Interface and Power-Up Test via the CFDS/MCDU AMM 23-73-00-740-005.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- Do the test given in Para. 3.
- remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
- during the installation of the DIR-CIDS, 1 (101RH) do not close these CBs:
49VU: 157RH COM CIDS/DIR ESS/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS,
120VU: 156RH COM NAV/CIDS/DIR NORM/2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2, - install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- Do the test given in Para. 3.
- install a new DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- Do the test given in Para. 3.
- remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001.
- open these CBs:
49VU: 153RH COM/CIDS/DEU B/ESS
121VU: 162RH COM NAV/CIDS/DEU B/NORM - make sure that the resistance (line to line) at DIR-CIDS (101RH) and (102RH) connector AA/D14 and connector AA/E14 is between approx. 80 and 140 ohms ASM 237306.
- make sure that the resistance (line to GND) is not less than 7 k ohms (short circuit) between:
DIR-CIDS (101RH) and (102RH) connector AA/D14 and GND,
DIR-CIDS (101RH) and (102RH) connector AA/E14 and GND. ASM 237306
- remove the DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-000-001.
- install the DIR-CIDS (101RH) and DIR-CIDS (102RH) AMM 23-73-34-400-001.
- close these CBs:
49VU: 153RH COM/CIDS/DEU B/ESS
121VU: 162RH COM NAV/CIDS/DEU B/NORM - Do the test given in Para. 3.
- install a new DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- Do the test given in Para. 3.
- install the removed DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- do the steps 4. B. (5) (a) again for the subsequent DEU(s) until the maintenance message stops: ASM 237306
DEU-B [300RH1]
- remove the DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-000-001.
- do a check for a short circuit again.
- install a new DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- Do the test given in Para. 3.
- disconnect the electrical connector from the DEU TERMINATION BOX [309RH1] ASM 237306.
- do a check for a short circuit again.
- install a new DEU TERMINATION BOX [309RH1] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- Do the test given in Para. 3.
- install the removed DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001,
- reconnect the electrical connector to the DEU TERMINATION BOX [309RH1] ,
- disconnect the electrical connector from the DEU CONNECTION BOX [308RH5] ,
- do a check for a short circuit again.
- b.1. If there is no short circuit:
- do a check for a short circuit at the disconnected connector between pin 9 and GND (pin 4) and between pin 10 and GND (pin 4).
- b.1.1. If there is a short circuit:
- repair the wiring between the DEU CONNECTION BOX [308RH5] and the DEU TERMINATION BOX [309RH1] ASM 237306.
- Do the test given in Para. 3.
- b.1.2. If there is no short circuit:
- install a new DEU CONNECTION BOX [308RH5] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- Do the test given in Para. 3.
- b.2. If there is a short circuit:
- reconnect the electrical connector to the DEU CONNECTION BOX [308RH5] ,
- do the steps (4. B. (5) (b) 2 b) again for the subsequent DEU(s) and DEU CONNECTION BOX(es) until the maintenance message stops for:
DEU-B [300RH1] and DEU CONNECTION BOX [308RH1] .
- disconnect the electrical connector DEU TERMINATION BOX [309RH1] ASM 237306,
- make sure that the resistance (line to line) is not more than 140 ohms (open circuit) between:
DEU TERMINATION BOX [309RH1] pin A/1 and pin A/2
- install a new DEU TERMINATION BOX [309RH1] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- Do the test given in Para. 3.
- reconnect the electrical connector to the DEU TERMINATION BOX [309RH1] .
- disconnect the electrical connector from the DEU CONNECTION BOX [308RH1] ASM 237306.
- do a check of the wiring (continuity-check) between:
DIR-CIDS (102RH) connector AA/D14 and the DEU CONNECTION BOX [308RH1] connector pin A/2,
DIR-CIDS (102RH) connector AA/E14 and the DEU CONNECTION BOX [308RH1] connector pin A/1.
- repair the wiring between the DIR-CIDS (102RH) and the connector DEU CONNECTION BOX [308RH1] ASM 237306.
- Do the test given in Para. 3.
- do a check of the wiring (continuity-check) between:
DEU CONNECTION BOX [308RH1] pin A/1 and pin A/9 ,
DEU CONNECTION BOX [308RH1] pin A/2 and pin A/10.
- install a new DEU CONNECTION BOX [308RH1] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- Do the test given in Para. 3.
- reconnect the connector to the DEU CONNECTION BOX [308RH1] .
- do the steps 4. B. (6) again for the subsequent DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops:
DIR-CIDS (102RH) and DEU CONNECTION BOX [308RH5] ,
DIR-CIDS (102RH) and DEU TERMINATION BOX [309RH1] .
- remove the DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-000-001.
- do a check for a short circuit again.
- install a new DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- Do the test given in Para. 3.
- install the removed DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- diconnect the electrical connector from the DEU TERMINATION BOX [309RH1] ASM 237306,
- do a check for a short circuit again.
- reconnect the electrical connector to the DEU TERMINATION BOX [309RH1] ,
- do the steps 4. B. (7) again for the subsequent DEU(s) and DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops for: ASM 237306
DEU CONNECTION BOX [308RH5] ,
DEU-B [300RH1] and DEU CONNECTION BOX [308RH1] ,
- do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306
- repair the wiring between the related DEU CONNECTION BOX 308RHxx and the DEU CONNECTION/ TERMINATION BOX(es) 308RHxx/309RHxx ASM 237306.
- Do the test given in Para. 3.
- install a new DEU TERMINATION BOX [309RH1] AMM 23-73-48-400-001.
- Do the test given in Para. 3.
B. If the test gives the maintenance message CIDS MID BUS L/DIR2 (102RH):
Subtask 23-73-00-810-780-A ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open.
- on the overhead panel 25VU:
make sure that the EMER EXIT LT switch (4WL) is in the OFF position. - remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001,
- close these CBs:
49VU: 157RH COM CIDS/DIR ESS/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS,
120VU: 156RH COM NAV/CIDS/DIR NORM/2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2. - wait for approx. 120s,
- do the CIDS2 Interface and Power-Up Test via the CFDS/MCDU AMM 23-73-00-740-005.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- Do the test given in Para. 3.
- remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
- during the installation of the DIR-CIDS, 1 [101RH] do not close these CBs:
49VU: 157RH COM CIDS/DIR ESS/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS,
120VU: 156RH COM NAV/CIDS/DIR NORM/2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2. - install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- Do the test given in Para. 3.
- install a new DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- Do the test given in Para. 3.
- remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001.
- open these CBs:
49VU: 153RH COM/CIDS/DEU B/ESS,
121VU: 193RH COM NAV/CIDS/DEU B/NORM FWD,
2001VU: 194RH DEU B/NORM AFT. - make sure that the resistance (line to line) at DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] connector AA/D14 and connector AA/E14 is between approx. 80 and 140 ohm ASM 237306.
- make sure that the resistance (line to GND) is not less than 7k ohm (short circuit) between:
DIR-CIDS (101RH) and (102RH) connector AA/D14 and GND,
DIR-CIDS (101RH) and (102RH) connector AA/E14 and GND. ASM 237306
- remove the DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-000-001,
- install the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- close these CBs:
49VU: 153RH COM/CIDS/DEU B/ESS,
121VU: 193RH COM NAV/CIDS/DEU B/NORM FWD,
2001VU: 194RH DEU B/NORM AFT. - Do the test given in Para. 3.
- install a new DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- Do the test given in Para. 3.
- install the removed DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- do the steps 4. B. (5) (a) again for the subsequent DEU(s) until the maintenance message stops: ASM 237306
DEU-B [300RH1]
- remove the DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-000-001,
- do a check for a short circuit again.
- install a new DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- Do the test given in Para. 3.
- disconnect the electrical connector from the DEU TERMINATION BOX [309RH1] ASM 237306,
- do a check for a short circuit again.
- install a new DEU TERMINATION BOX [309RH1] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- Do the test given in Para. 3.
- install the removed DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001,
- reconnect the electrical connector to the DEU TERMINATION BOX [309RH1] ,
- disconnect the electrical connector from the DEU CONNECTION BOX [308RH5] ,
- do a check for a short circuit again.
- b.1. If there is no short circuit:
- do a check for a short circuit at the disconnected connector between pin 9 and GND (pin 4) and between pin 10 and GND (pin 4).
- b.1.1. If there is a short circuit:
- repair the wiring between the DEU CONNECTION BOX [308RH5] and the DEU TERMINATION BOX [309RH1] ASM 237306.
- Do the test given in Para. 3.
- b.1.2. If there is no short circuit:
- install a new DEU CONNECTION BOX [308RH5] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- Do the test given in Para. 3.
- b.2. If there is a short circuit:
- reconnect the electrical connector to the DEU CONNECTION BOX [308RH5] ,
- do the steps (4. B. (5) (b) 2 b) again for the subsequent DEU(s) and DEU CONNECTION BOX(es) until the maintenance message stops for:
DEU CONNECTION BOX [308RH3]
DEU-B [300RH1] and DEU CONNECTION BOX [308RH1] .
- disconnect the electrical connector DEU TERMINATION BOX [309RH1] ASM 237306,
- make sure that the resistance (line to line) is not more than 140 ohm (open circuit) between:
DEU TERMINATION BOX [309RH1] pin A/1 and pin A/2
- install a new DEU TERMINATION BOX [309RH1] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- Do the test given in Para. 3.
- reconnect the electrical connector to the DEU TERMINATION BOX [309RH1] ,
- disconnect the electrical connector from the DEU CONNECTION BOX [308RH1] ASM 237306.
- do a check of the wiring (continuity-check) between:
DIR-CIDS (102RH) connector AA/D14 and the DEU CONNECTION BOX [308RH1] connector pin A/2,
DIR-CIDS (102RH) connector AA/E14 and the DEU CONNECTION BOX [308RH1] connector pin A/1.
- repair the wiring between the DIR-CIDS (102RH) and the connector DEU CONNECTION BOX [308RH1] ASM 237306.
- Do the test given in Para. 3.
- do a check of the wiring (continuity-check) between:
DEU CONNECTION BOX [308RH1] pin A/1 and pin A/9 ,
DEU CONNECTION BOX [308RH1] pin A/2 and pin A/10.
- install a new DEU CONNECTION BOX [308RH1] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- Do the test given in Para. 3.
- reconnect the connector to the DEU CONNECTION BOX [308RH1] .
- do the steps 4. B. (6) again for the subsequent DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops:
DIR-CIDS (102RH) and DEU CONNECTION BOX [308RH3] ,
DIR-CIDS (102RH) and DEU CONNECTION BOX [308RH5] ,
DIR-CIDS (102RH) and DEU TERMINATION BOX [309RH1] .
- remove the DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-000-001,
- do a check for a short circuit again.
- install a new DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001.
- Do the test given in Para. 3.
- install the removed DECODER/ENCODER UNIT B [300RH7] AMM 23-73-47-400-001,
- disconnect the electrical connector from the DEU TERMINATION BOX [309RH1] ASM 237306,
- do a check for a short circuit again.
- reconnect the electrical connector to the DEU TERMINATION BOX [309RH1] ,
- do the steps 4. B. (7) again for the subsequent DEU(s) and DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops for: ASM 237306
DEU CONNECTION BOX [308RH3] ,
DEU CONNECTION BOX [308RH5] ,
DEU-B [300RH1] and DEU CONNECTION BOX [308RH1] .
- do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306.
- repair the wiring between the related DEU CONNECTION BOX 308RHxx and the DEU CONNECTION/ TERMINATION BOX(es) 308RHxx/309RHxx ASM 237306.
- Do the test given in Para. 3.
- install a new DEU TERMINATION BOX [309RH1] AMM 23-73-48-400-001.
- Do the test given in Para. 3.
C. Installation of removed components
Subtask 23-73-00-810-780-B ** ON A/C NOT FOR ALL - Install the removed DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- Install all the removed DEU-B (300RHxx) AMM 23-73-47-400-001.
- Reconnect all the DEU-mount-connectors to the related DEU-mounts (2011VUxx/2015VUx) AMM 23-73-48-400-001.
C. Installation of removed components
Subtask 23-73-00-810-781-A - Install the removed DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- Install all the removed DEU-B (300RHxx) AMM 23-73-47-400-001.
- Reconnect all the DEU CONNECTION/ TERMINATION BOX-connectors to the related DEU CONNECTION/ TERMINATION BOX ASM 237306.
- Make sure that all previously opened CBs are closed.
D. Do the test given in Para. 3.A.