PISA data transfer failure


TASK 23-73-00-810-970-A
PISA data transfer failure


1. Possible Causes
  • PISA
  • DEU-A 200RHxx
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237314
AMM 23-73-41-000-001
Removal of the Passenger Interface and Supply Adapter (602RH)
AMM 23-73-41-400-001
Installation of the Passenger Interface and Supply Adapter (602RH)
AMM 23-73-46-000-001
Removal of the Decoder/Encoder Unit A (200RH)
AMM 23-73-46-400-001
Installation of the Decoder/Encoder Unit A (200RH)
3. Fault Confirmation
Subtask 23-73-00-710-390-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 23-73-00-810-762-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-763-A ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring between:
    PISA and the related DEU-A 200RHxx with the signal name 28VDC IN/OUT,
    PISA and the related DEU-A 200RHxx with the signal name DC GND IN,
    PISA and the related DEU-A 200RHxx with the signal name LVDS P,
    PISA and the related DEU-A 200RHxx with the signal name LVDS N,
    ASM 237314
5. Close-up
Subtask 23-73-00-710-391-A ** ON A/C NOT FOR ALL
A. Do the test given in para. 3.A.