W DOC AIRBUS | TSM A320F

PA on Battery Power - No announcement possible


TASK 23-73-00-810-969-A
PA on Battery Power - No announcement possible


1. Possible Causes
  • DIR-CIDS, 1 [101RH]
  • DIR-CIDS, 2 [102RH]
  • C/B-COM/CIDS/DIR 2/BAT [146RH]
  • C/B-COM/CIDS/DIR 1/BAT [147RH]
  • C/B-COM/CIDS/BAT/CTL [148RH]
  • wiring
  • relay 107RH
  • relay 106RH
  • emer exit light switch 4WL
  • relay 108RH
  • relay 103RH
  • relay 109RH
  • relay 112RH
  • relay 212RH
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-710-006
Operational Test of the Battery-Bus powered PA
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237306
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-73-00-700-059-A ** ON A/C NOT FOR ALL
A. Test:
   (1) Do the CIDS Interface and Power-Up test through the CFDS
AMM 23-73-00-740-005.
   (2) Do the Operational test of the battery-bus powered PA
AMM 23-73-00-710-006.
Subtask 23-73-00-700-059-B ** ON A/C NOT FOR ALL
A. Test:
   (1) Do the CIDS Interface and Power-Up test through the CFDS
AMM 23-73-00-740-005.
   (2) Do the Operational test of the battery-bus powered PA
AMM 23-73-00-710-006.
4. Fault Isolation
Subtask 23-73-00-810-760-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-759-B ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
  • remove the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH]
    AMM 23-73-34-000-001.
  • close the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
  • do a check for 28 VDC at the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
   (1) If there is no 28VDC at one or more circuit breaker:
  • Replace the related circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
   (2) If there is 28VDC at all circuit breakers:
  • open the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
     (a) do a check of the wiring between:
  • the DIR-CIDS, 1 [101RH] and the relay 107RH ,
  • the DIR-CIDS, 2 [102RH] and the relay 107RH ,
  • the DIR-CIDS, 1 [101RH] and the relay 106RH ,
  • the DIR-CIDS, 2 [102RH] and the relay 106RH ,
  • the emer exit light switch 4WL and the relay 108RH ,
  • the circuit breaker C/B-COM/CIDS/BAT/CTL [148RH] and the relay 107RH ,
  • the circuit breaker C/B-COM/CIDS/BAT/CTL [148RH] and the relay 103RH ,
  • the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] and the relay 107RH ,
  • the circuit breaker C/B-COM/CIDS/DIR 1/BAT [147RH] and the relay 107RH ,
  • the relay 109RH and the relay 103RH ,
  • the relay 109RH and the relay 107RH ,
  • the relay 109RH and the relay 108RH ,
    ASM 237306 and ASM 237306.
       1 If the fault continues:
         a do a check and replace, if necessary:
  • the relay 103RH,
  • the relay 106RH,
  • the relay 107RH,
  • the relay 108RH,
  • the relay 109RH,
  • the emer exit light switch 4WL.
   (3) install the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH]
AMM 23-73-34-400-001.
Subtask 23-73-00-810-759-C ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
  • remove the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH]
    AMM 23-73-34-000-001.
  • Close the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
  • Do a check for 28 VDC at the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
   (1) If there is no 28VDC at one or more circuit breaker:
  • replace the related circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
   (2) If there is 28VDC at all circuit breakers:
  • open the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
     (a) Do a check of the wiring between:
  • the DIR-CIDS, 1 [101RH] and the relay 103RH ,
  • the DIR-CIDS, 2 [102RH] and the relay 103RH ,
  • the DIR-CIDS, 1 [101RH] and the relay 106RH ,
  • the DIR-CIDS, 2 [102RH] and the relay 106RH ,
  • the emer exit light switch 4WL and the relay 108RH ,
  • the circuit breaker C/B-COM/CIDS/BAT/CTL [148RH] and the relay 107RH ,
  • the circuit breaker C/B-COM/CIDS/BAT/CTL [148RH] and the relay 103RH ,
  • the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] and the relay 103RH ,
  • the circuit breaker C/B-COM/CIDS/DIR 1/BAT [147RH] and the relay 103RH ,
  • the relay 109RH and the relay 103RH ,
  • the relay 109RH and the relay 107RH ,
  • the relay 109RH and the relay 108RH ,
    ASM 237306 and ASM 237306.
       1 If the fault continues:
         a do a check and replace, if necessary:
  • the relay 103RH,
  • the relay 106RH,
  • the relay 107RH,
  • the relay 108RH,
  • the relay 109RH,
  • the emer exit light switch 4WL.
   (3) install the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH]
AMM 23-73-34-400-001.
Subtask 23-73-00-810-759-D ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
  • remove the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH]
    AMM 23-73-34-000-001.
  • close the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
  • do a check for 28 VDC at the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
   (1) If there is no 28VDC at one or more circuit breaker:
  • replace the related circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
   (2) If there is 28VDC at all circuit breakers:
  • open the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] , C/B-COM/CIDS/DIR 1/BAT [147RH] and C/B-COM/CIDS/BAT/CTL [148RH] .
     (a) Do a check of the wiring between:
  • the DIR-CIDS, 1 [101RH] and the relay 103RH ,
  • the DIR-CIDS, 2 [102RH] and the relay 103RH ,
  • the DIR-CIDS, 1 [101RH] and the relay 106RH ,
  • the DIR-CIDS, 2 [102RH] and the relay 106RH ,
  • the DIR-CIDS, 1 [101RH] and the relay 112RH ,
  • the DIR-CIDS, 2 [102RH] and the relay 112RH ,
  • the emer exit light switch 4WL and the relay 108RH ,
  • the C/B-COM/CIDS/BAT/CTL [148RH] and the relay 107RH ,
  • the circuit breaker C/B-COM/CIDS/BAT/CTL [148RH] and the relay 103RH ,
  • the circuit breaker C/B-COM/CIDS/BAT/CTL [148RH] and the relay 212RH ,
  • the circuit breaker C/B-COM/CIDS/DIR 2/BAT [146RH] and the relay 103RH ,
  • the circuit breaker C/B-COM/CIDS/DIR 1/BAT [147RH] and the relay 103RH ,
  • the relay 109RH and the relay 103RH ,
  • the relay 109RH and the relay 107RH ,
  • the relay 109RH and the relay 108RH ,
  • the relay 109RH and the relay 212RH ,
    ASM 237306 and ASM 237306.
       1 If the fault continues:
         a do a check and replace, if necessary:
  • the relay 103RH,
  • the relay 106RH,
  • the relay 107RH,
  • the relay 108RH,
  • the relay 109RH,
  • the relay 112RH,
  • the relay 212RH,
  • the emer exit light switch 4WL.
   (3) install the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH]
AMM 23-73-34-400-001.
Subtask 23-73-00-810-761-A ** ON A/C NOT FOR ALL
C. If the fault continues:
5. Close-up
Subtask 23-73-00-942-055-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:26:01 UTC