DIR 2 - Loss of normal power (28VDC2 SPLY)
TASK 23-73-00-810-968-A
DIR 2 - Loss of normal power (28VDC2 SPLY)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-865-051-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-757-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-942-054-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:01 UTC
DIR 2 - Loss of normal power (28VDC2 SPLY)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237306 | |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-865-051-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 23-73-00-700-058-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M07 |
B. Do the CIDS Interface and Power-Up test through the CFDS AMM 23-73-00-740-005
(1) If you cannot close the circuit breaker 156RH, go to Para 4. B.
4. Fault Isolation(1) If you cannot close the circuit breaker 156RH, go to Para 4. B.
Subtask 23-73-00-810-757-A ** ON A/C NOT FOR ALL
A. If the circuit breaker C/B-COM NAV/CIDS/DIR NORM/2 [156RH] is closed and the test confirmes the fault:
Subtask 23-73-00-810-758-A ** ON A/C NOT FOR ALL - remove the DIR-CIDS, 2 [102RH]
AMM 23-73-34-000-001. - close the C/B-COM NAV/CIDS/DIR NORM/2 [156RH]
- do a check for 28 VDC at the DIR connector AC/4
ASM 237306 and ASM 237306.
- open the C/B-COM NAV/CIDS/DIR NORM/2 [156RH] .
- Install a new DIR-CIDS, 2 [102RH]
AMM 23-73-34-400-001.
- do a check for 28 VDC at the C/B-COM/CIDS/DIR ESS/1 [150RH] .
- open the C/B-COM NAV/CIDS/DIR NORM/2 [156RH] .
- do a check of the wiring between the:
DIR-CIDS, 2 [102RH] connector AC/4 and C/B-COM NAV/CIDS/DIR NORM/2 [156RH]
ASM 237306 and ASM 237306.
B. If the circuit breaker C/B-COM NAV/CIDS/DIR NORM/2 [156RH] is open:
5. Close-up- close this circuit breaker.
- remove the DIR-CIDS, 2 [102RH]
AMM 23-73-34-000-001. - do a check for a short to ground between the circuit breaker C/B-COM NAV/CIDS/DIR NORM/2 [156RH] and the DIR-CIDS, 2 [102RH]
ASM 237306 and ASM 237306.
- repair the wiring .
- close the circuit breaker C/B-COM NAV/CIDS/DIR NORM/2 [156RH] .
- replace the C/B-COM NAV/CIDS/DIR NORM/2 [156RH] .
- open the C/B-COM NAV/CIDS/DIR NORM/2 [156RH] .
- Install a new DIR-CIDS, 2 [102RH]
AMM 23-73-34-400-001.
Subtask 23-73-00-942-054-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.