DIR 1 - Loss of essential power (28VDC1 SPLY)
TASK 23-73-00-810-965-A
DIR 1 - Loss of essential power (28VDC1 SPLY)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-865-052-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-751-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-942-051-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:00 UTC
DIR 1 - Loss of essential power (28VDC1 SPLY)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237306 | |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-865-052-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 23-73-00-700-055-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DIR ESS/1 | 150RH | G01 |
B. Do the CIDS Interface and Power-Up test through the CFDS AMM 23-73-00-740-005.
(1) If you cannot close the circuit breaker (150RH), go to Para 4. B.
4. Fault Isolation(1) If you cannot close the circuit breaker (150RH), go to Para 4. B.
Subtask 23-73-00-810-751-A ** ON A/C NOT FOR ALL
A. If the circuit breaker C/B-COM/CIDS/DIR ESS/1 [150RH] is closed and the test confirmes the fault:
Subtask 23-73-00-810-752-A ** ON A/C NOT FOR ALL - remove the DIR-CIDS, 1 [101RH]
AMM 23-73-34-000-001. - close the C/B-COM/CIDS/DIR ESS/1 [150RH] .
- do a check for 28 VDC at the DIR connector AC/1
ASM 237306 and ASM 237306.
- open the C/B-COM/CIDS/DIR ESS/1 [150RH] .
- install a new DIR-CIDS, 1 [101RH] .
AMM 23-73-34-400-001.
- do a check for 28 VDC at the C/B-COM/CIDS/DIR ESS/1 [150RH] .
- open the C/B-COM/CIDS/DIR ESS/1 [150RH] .
- do a check of the wiring between the:
DIR-CIDS, 1 [101RH] connector AC/1 and C/B-COM/CIDS/DIR ESS/1 [150RH]
ASM 237306 and ASM 237306.
B. If the circuit breaker C/B-COM/CIDS/DIR ESS/1 [150RH] is open:
5. Close-up- close this circuit breaker.
- remove the DIR-CIDS, 1 [101RH]
AMM 23-73-34-000-001. - do a check for a short to ground between the circuit breaker C/B-COM/CIDS/DIR ESS/1 [150RH] and the DIR-CIDS, 1 [101RH]
ASM 237306 and ASM 237306.
- repair the wiring .
- close the circuit breaker C/B-COM/CIDS/DIR ESS/1 [150RH] .
- replace the C/B-COM/CIDS/DIR ESS/1 [150RH] .
- open the circuit breaker C/B-COM/CIDS/DIR ESS/1 [150RH] .
- install a new DIR-CIDS, 1 [101RH]
AMM 23-73-34-400-001.
Subtask 23-73-00-942-051-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.