W DOC AIRBUS | TSM A320F

STA PISA (xxxLZ) or DEU A fault


TASK 23-73-00-810-954-A
STA PISA (xxxLZ) or DEU A fault


1. Possible Causes
  • STA PISA (XXXLZ)
  • DEU A 200RHYY
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237307
ASM 237314
AMM 23-73-46-000-001
Removal of the Decoder/Encoder Unit A (200RH)
AMM 23-73-46-400-001
Installation of the Decoder/Encoder Unit A (200RH)
AMM 33-27-41-000-001
Removal of the Stand-Alone Passenger Interface and Supply Adapter (StA-PISA)
AMM 33-27-41-400-001
Installation of the Stand-Alone Passenger Interface and Supply Adapter (StA-PISA)
3. Fault Confirmation
Subtask 23-73-00-710-387-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up Test through the CFDS.
AMM 23-73-00-740-005
4. Fault Isolation
Subtask 23-73-00-810-745-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble-shooting procedure related to the maintenance message.
Subtask 23-73-00-810-746-A ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
   (1) If the fault continues:
   (2) If the fault continues:
  • Do a check and repair the wiring between:
    STA PISA connector A / signal LVDS P and the related DEU A 200RH connector C / signal LVDS P,
    STA PISA connector A / signal LVDS N and the related DEU A 200RH connector C / signal LVDS N,
    STA PISA connector A / signal CHASSIS GND and the related DEU 200RH connector C / signal GND,
    STA PISA connector A / signal 28VDC and the related DEU 200RH connector C / signal 28VDC,
    STA PISA connector A / signal DC GND and the related DEU 200RH connector C / signal DC GND,
    ASM 237307 ASM 237314
5. Close-up
Subtask 23-73-00-710-388-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:00 UTC