CAM/PTP Fault
TASK 23-73-00-810-952-A
CAM/PTP Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-386-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-740-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-710-389-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:00 UTC
CAM/PTP Fault
1. Possible Causes
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237309 |
Subtask 23-73-00-710-386-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-740-A ** ON A/C NOT FOR ALL
A. If the fault continues:
Subtask 23-73-00-810-737-A ** ON A/C NOT FOR ALL - do a check and repair the wiring between:
CB 161RH and PTP connector A/17,
DIR-CIDS (101RH) connector AA/F12 and PTP (110RH) connector A/1,
DIR-CIDS (101RH) connector AA/G12 and PTP (110RH) connector A/2,
DIR-CIDS (102RH) connector AA/F12 and PTP (110RH) connector A/6,
DIR-CIDS (102RH) connector AA/G12 and PTP (110RH) connector A/7,
DIR-CIDS (101RH) connector AA/J12 and PTP (110RH) connector A/4,
DIR-CIDS (101RH) connector AA/K12 and PTP (110RH) connector A/5,
DIR-CIDS (102RH) connector AA/J12 and PTP (110RH) connector A/4,
DIR-CIDS (102RH) connector AA/K12 and PTP (110RH) connector A/5,
PTP (110RH) connector A/3 and GND,
PTP (110RH) connector A/8 and GND,
PTP (110RH) connector A/16 and GND ASM 237309.
B. If the fault continues, do the trouble shooting procedure related to the maintenance message.
5. Close-upSubtask 23-73-00-710-389-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the test given in Para. 3.
(1) Do the test given in Para. 3.