DIR 2 / OBRM failure
TASK 23-73-00-810-938-A
DIR 2 / OBRM failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-365-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-700-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-710-366-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:59 UTC
DIR 2 / OBRM failure
1. Possible Causes
- DIR-CIDS, 2 [102RH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-365-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-700-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-701-A ** ON A/C NOT FOR ALL B. If the test confirms the fault:
5. Close-up- replace the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
Subtask 23-73-00-710-366-A ** ON A/C NOT FOR ALL
A. Do the test given in para. 3.