W DOC AIRBUS | TSM A320F

CAM/DIR 2 software mismatch


TASK 23-73-00-810-936-A
CAM/DIR 2 software mismatch


1. Possible Causes
  • MODULE-CABIN ASSIGNMENT [115RH]
  • CIDS OBRM [116RH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
3. Fault Confirmation
Subtask 23-73-00-710-361-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 23-73-00-810-696-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-697-A ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
  • make sure that the MODULE-CABIN ASSIGNMENT [115RH] standart is in accordance with the CIDS OBRM [116RH] standart.
5. Close-up
Subtask 23-73-00-710-362-A ** ON A/C NOT FOR ALL
A. Do the test given in para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:59 UTC