PAX CALL lamp at LAV(x) fault
TASK 23-73-00-810-929-A
PAX CALL lamp at LAV(x) fault
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-346-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-677-A
Subtask 23-73-00-710-350-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:58 UTC
PAX CALL lamp at LAV(x) fault
1. Possible Causes
PAX CALL LAMP / LAVATORY CALL LIGHT - wiring
DEU-A (200RHxx)
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-710-033 | Operational Test of the Passenger Call Lamps through the MCDU |
| AMM 23-73-00-710-035 | Operational Test of the Cabin LED lamps through the MCDU |
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237307 | |
| AMM 23-73-14-000-001 | Removal of the Lavatory Call Light |
| AMM 23-73-14-400-001 | Installation of the Lavatory Call Light |
| ASM 237318 | |
| ASM 237319 | |
| AMM 23-73-46-000-001 | Removal of the Decoder/Encoder Unit A (200RH) |
| AMM 23-73-46-400-001 | Installation of the Decoder/Encoder Unit A (200RH) |
Subtask 23-73-00-710-346-A ** ON A/C NOT FOR ALL
A. Test for the Pax Call Lamps / Lavatory Call Lights
(1) Do the CIDS1/SIGN LAMP test through the CFDS AMM 23-73-00-710-033.
Subtask 23-73-00-710-346-B ** ON A/C NOT FOR ALL (1) Do the CIDS1/SIGN LAMP test through the CFDS AMM 23-73-00-710-033.
NOTE: An erroneous class 3 fault message will be recorded for each LED PAX CALL LAMP (without bulbs), if the test of the related lamps is not deactivated in the CAM.
(2) Push the Call Button in the related lavatory to make sure that the related Pax Call Lamp / Lavatory Call Light comes on. A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
(2) Do the Operational Test of the Cabin LED Lamps via the CFDS AMM 23-73-00-710-035.
4. Fault Isolation(1) Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
(2) Do the Operational Test of the Cabin LED Lamps via the CFDS AMM 23-73-00-710-035.
Subtask 23-73-00-810-677-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-678-A ** ON A/C NOT FOR ALL B. If the CIDS1/SIGN LAMP test gives the maintenance message PAX CALL LAMP LAV X and the lamp does not come on:
Subtask 23-73-00-810-678-B ** ON A/C NOT FOR ALL NOTE: X identifies the location of the affected lavatory.
- replace the related
PAX CALL LAMP / LAVATORY CALL LIGHT AMM 23-73-14-000-001 and AMM 23-73-14-400-001.
- do a check for 28 VDC with a MULTIMETER - STANDARD at the related DEU-A between the related pairs of connectors given below:
Connectors C/7 and C/18 or
Connectors C/9 and C/19 or
Connectors C/11 and C/20 ASM 237307, ASM 237318 and ASM 237319.
- do a check and repair the wiring if necessary between the:
Pins 1 and 2 of the related Pax Call Lamp / Lavatory Call Light and the related DEU-A pairs of connectors given below:
Connectors C/7 and C/18 or
Connectors C/9 and C/19 or
Connectors C/11 and C/20 ASM 237307, ASM 237318 and ASM 237319.
- replace the related
DEU-A (200RHxx) AMM 23-73-46-000-001 and AMM 23-73-46-400-001.
B. If the test confirms the fault:
Subtask 23-73-00-810-679-A ** ON A/C NOT FOR ALL - replace the related
PAX CALL LAMP / LAVATORY CALL LIGHT AMM 23-73-14-000-001 and AMM 23-73-14-400-001.
- do a check for 28 VDC with a MULTIMETER - STANDARD at the related DEU-A connector at the signal names:
Call L.1 OUT and DC GND
ASM 237307, ASM 237318 and ASM 237319.
- do a check and repair the wiring if necessary between the:
DEU-A (200RHxx) and the related Pax Call Lamp / Lavatory Call Light with the signal names:
CALL L.1 OUT and DC GND.
ASM 237307, ASM 237318 and ASM 237319.
- replace the related
DEU-A (200RHxx) AMM 23-73-46-000-001 and AMM 23-73-46-400-001.
C. If the CIDS1/SIGN LAMP test gives the maintenance message PAX CALL LAMP XX and the lamps come on, no other maintenance action is necessary.
5. Close-upNOTE: An erroneous class 3 fault message will be recorded for each LED PAX CALL LAMP (without bulbs), if the test of the related lamps is not deactivated in the CAM.
Subtask 23-73-00-710-350-A
A. Do the test as given in Para. 3.A.