W DOC AIRBUS | TSM A320F

FAP - Passive Director no data from FAP(x)


TASK 23-73-00-810-925-A
FAP - Passive Director no data from FAP(x)


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-12-000-007
Removal of the Flight Attendant Panel
AMM 23-73-12-400-007
Installation of the Flight Attendant Panel
ASM 237323
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-73-00-710-339-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 23-73-00-810-669-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-670-A ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring between:
  • FAP [120RH] connector A/5 and DIR-CIDS, 2 [102RH] connector AA/5A
  • FAP [120RH] connector A/6 and DIR-CIDS, 2 [102RH] connector AA/5B
  • FAP [120RH] connector A/7 and DIR-CIDS, 2 [102RH] connector AA/13C
  • FAP [120RH] connector A/8 and DIR-CIDS, 2 [102RH] connector AA/13D
    ASM 237323
5. Close-up
Subtask 23-73-00-710-340-A ** ON A/C NOT FOR ALL
A. Do the test as given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:57 UTC