W DOC AIRBUS | TSM A320F

FAP - Active Director no data from FAP(x)


TASK 23-73-00-810-924-A
FAP - Active Director no data from FAP(x)


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-12-000-007
Removal of the Flight Attendant Panel
AMM 23-73-12-400-007
Installation of the Flight Attendant Panel
ASM 237323
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-73-00-710-337-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up test through the CFDS.
AMM 23-73-00-740-005
4. Fault Isolation
Subtask 23-73-00-810-667-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-668-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message FAP <NAME> (120RH)/DIR1 (101RH):
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring between:
  • FAP <NAME> (120RH) connector A/1 and DIR1 (101RH) connector AA/5A,
  • FAP <NAME> (120RH) connector A/2 and DIR1 (101RH) connector AA/5B,
  • FAP <NAME> (120RH) connector A/3 and DIR1 (101RH) connrctor AA/13C,
  • FAP <NAME> (120RH) connector A/4 and DIR1 (101RH) connector AA/13D.
    ASM 237323
5. Close-up
Subtask 23-73-00-710-338-A ** ON A/C NOT FOR ALL
A. Do the test as given in Para. 3.A.