CAM - Layout transmission fail to active Director
TASK 23-73-00-810-920-A
CAM - Layout transmission fail to active Director
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-328-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-658-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-710-329-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:57 UTC
CAM - Layout transmission fail to active Director
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-12-000-007 | Removal of the Flight Attendant Panel |
| AMM 23-73-12-400-007 | Installation of the Flight Attendant Panel |
| AMM 23-73-19-000-002 | Removal of the Cabin Assignment Module |
| AMM 23-73-19-400-002 | Installation of the Cabin Assignment Module |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-328-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-658-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-659-A ** ON A/C NOT FOR ALL B. If the test confirms the fault:
5. Close-up- replace the MODULE-CABIN ASSIGNMENT [115RH] AMM 23-73-19-000-002 and AMM 23-73-19-400-002
- replace the FAP [120RH] AMM 23-73-12-000-007 and AMM 23-73-12-400-007.
- replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
Subtask 23-73-00-710-329-A ** ON A/C NOT FOR ALL
A. Do the test as given in Para. 3.A.