FAP - FAP(x) no data from passive Director
TASK 23-73-00-810-919-A
FAP - FAP(x) no data from passive Director
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-326-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-656-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-710-327-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:57 UTC
FAP - FAP(x) no data from passive Director
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-12-000-007 | Removal of the Flight Attendant Panel |
| AMM 23-73-12-400-007 | Installation of the Flight Attendant Panel |
| ASM 237323 | |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-326-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-656-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-657-A ** ON A/C NOT FOR ALL B. If the test confirms the fault:
5. Close-up- replace DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
- replace the FAP [120RH] AMM 23-73-12-000-007 and AMM 23-73-12-400-007
- do a check and repair the wiring between:
DIR-CIDS, 2 [102RH] connector AA/5A and FAP [120RH] connector A/5,
DIR-CIDS, 2 [102RH] connector AA/5B and FAP [120RH] connector A/6,
ASM 237323.
Subtask 23-73-00-710-327-A ** ON A/C NOT FOR ALL
A. Do the test as given in Para. 3.A.