W DOC AIRBUS | TSM A320F

Handset failure


TASK 23-73-00-810-917-A
Handset failure


1. Possible Causes
  • Handset 330RHxx
  • DEU-B 300RHxx
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237324
AMM 23-73-44-000-001
Removal of the Handset/Cradle
AMM 23-73-44-400-001
Installation of the Handset/Cradle
AMM 23-73-47-000-001
Removal of the Decoder/Encoder Unit B (300RH)
AMM 23-73-47-400-001
Installation of the Decoder/Encoder Unit B (300RH)
3. Fault Confirmation
Subtask 23-73-00-710-322-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 23-73-00-810-652-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-653-A ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check of the wiring between the related DEU-B 300RHxx and the related Handset 330RHxx with the signal names:
    AUD HI
    AUD LO
    MIC HI
    MIC LO
    PTT
    DC GND
    ASM 237324
5. Close-up
Subtask 23-73-00-710-323-A ** ON A/C NOT FOR ALL
A. Do the test as given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:56 UTC