FAP - FAP(x) fault caused by active Director
TASK 23-73-00-810-916-A
FAP - FAP(x) fault caused by active Director
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-320-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-650-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-710-321-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:56 UTC
FAP - FAP(x) fault caused by active Director
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-12-000-007 | Removal of the Flight Attendant Panel |
| AMM 23-73-12-400-007 | Installation of the Flight Attendant Panel |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-320-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-650-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-651-A ** ON A/C NOT FOR ALL B. If the test confirms the fault:
(1) Do a reset:
(a) Make sure that at least one cabin door is open.
(b) Open these CBs:
(d) Stop for approx. 120 s.
(e) Do the test again with CIDS 2 in Active mode.
1 If the fault continues:
a Replace the FAP [120RH] AMM 23-73-12-000-007 and AMM 23-73-12-400-007.
2 If the test is OK:
a Replace DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001
(2) If the fault continues:
(a) Do a check and repair the wiring between:
5. Close-up(1) Do a reset:
(a) Make sure that at least one cabin door is open.
(b) Open these CBs:
- 49VU: 150RH COM/CIDS/DIR ESS/1
- 49VU: 157RH COM/CIDS/DIR ESS/2
- 49VU: 15WH AIR COND/CIDS/SDF/DIR 1 ESS
- 49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS
- 121VU: 151RH COM NAV/CIDS/DIR NORM/1
- 121VU: 156RH COM NAV/CIDS/DIR NORM/2
- 122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2
- 122VU: 17WH AIR COND/CIDS/SDF/DIR NORM/1.
(d) Stop for approx. 120 s.
(e) Do the test again with CIDS 2 in Active mode.
1 If the fault continues:
a Replace the FAP [120RH] AMM 23-73-12-000-007 and AMM 23-73-12-400-007.
2 If the test is OK:
a Replace DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001
(2) If the fault continues:
(a) Do a check and repair the wiring between:
Subtask 23-73-00-710-321-A ** ON A/C NOT FOR ALL
A. Do the test as given in Para. 3.A.